Test for Ammonium: Nessler's Reagent and Alkali Heating
Detect NH₄⁺ by ammonia evolution on warming with NaOH and by Nessler's reagent.
Theoretical Foundations
Warming NH₄⁺ salts with NaOH liberates NH₃: NH₄⁺ + OH⁻ → NH₃↑ + H₂O — detected by smell, moist red litmus turning blue, or white NH₄Cl fumes with HCl. Nessler's reagent (K₂[HgI₄] + KOH) gives a brown precipitate/colour with traces of NH₃: the most sensitive test.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Litmus paper
- Glass rod
- Dropper
Chemical Reagents
- Ammonium chloride (~0.1 M)
- Sodium hydroxide (~2 M)
- Nessler's reagent
- Concentrated HCl (fume test)
Step-by-Step Practical Procedure
- Warm NH₄Cl with NaOH: test the gas with moist red litmus (turns blue).
- Hold a glass rod dipped in conc. HCl in the gas: white fumes of NH₄Cl.
- Add Nessler's reagent to dilute NH₄⁺: brown colour/precipitate.
- Run a Na⁺ control — negative throughout.
Observations & Expected Results
Pungent gas, blue litmus, white fumes, brown Nessler's reaction.
Worked Stoichiometric Calculations
Problem: Nessler's test detects ~0.3 ppm NH₃. Why is it the most sensitive?
Working: The Hg–I–NH₃ chromophore has an enormous molar absorptivity — colour appears at trace levels.
Safety Precautions & Hazard Control
- Nessler's reagent contains mercury — gloves, tiny amounts.
- NH₃ fumes — do not inhale directly (waft).
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Mercury-containing Nessler waste to mercury waste.
Viva Voce Oral Defense Questions & Answers
Q: Why warm and not boil?
A: Gentle warming releases NH₃ steadily; boiling sprays NaOH and gives false litmus readings.
Q: Why the HCl rod test?
A: NH₃ + HCl → NH₄Cl white fumes — specific for volatile base.