Confirmatory Test for Manganese: Oxidation to Permanganate
Confirm Mn²⁺ by oxidation to purple MnO₄⁻ with PbO₂, NaBiO₃ or persulphate/Ag⁺.
Theoretical Foundations
Strong oxidants convert Mn²⁺ to MnO₄⁻ in acid: 2Mn²⁺ + 5PbO₂ + 4H⁺ → 2MnO₄⁻ + 5Pb²⁺ + 2H₂O. The intense purple colour is unmistakable and very sensitive. Sodium bismuthate (NaBiO₃) is the classical solid oxidant; persulphate with Ag⁺ catalyst is the modern alternative.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Water bath
- Filter paper
- Test-tube rack
Chemical Reagents
- Manganese(II) sulphate (~0.1 M)
- Sodium bismuthate (solid) or PbO₂
- Dilute HNO₃ (~2 M)
- Dilute H₂SO₄
Step-by-Step Practical Procedure
- Acidify Mn²⁺ solution with dilute HNO₃.
- Add a pinch of NaBiO₃ (or PbO₂) and warm; filter off excess oxidant.
- Intense purple filtrate = MnO₄⁻ = Mn²⁺ confirmed.
- Compare with a blank (no manganese) — stays colourless.
Observations & Expected Results
Colourless → intense purple on oxidation.
Worked Stoichiometric Calculations
Problem: Balance: Mn²⁺ + BiO₃⁻ + H⁺ → MnO₄⁻ + Bi³⁺ + H₂O (acidic).
Working: 2Mn²⁺ + 5BiO₃⁻ + 14H⁺ → 2MnO₄⁻ + 5Bi³⁺ + 7H₂O.
Safety Precautions & Hazard Control
- NaBiO₃/PbO₂ are strong oxidants — keep from organics.
- Lead waste if PbO₂ used.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Manganese/lead/bismuth residues to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why filter before judging the colour?
A: Excess solid oxidant (brown PbO₂) would mask the purple.
Q: Why HNO₃ and not HCl for acidification?
A: HCl would be oxidised to Cl₂ by these strong oxidants, consuming reagent and giving false chemistry.