Group IV Precipitation: H₂S in Ammoniacal Medium
Precipitate CoS, NiS, MnS and ZnS from ammoniacal solution and note their colours.
Theoretical Foundations
After Group III removal, the filtrate is made ammoniacal and H₂S is passed: CoS (black), NiS (black), MnS (buff/flesh-coloured), ZnS (white/grey) precipitate (typical Ksp: CoS ~10⁻²¹, NiS ~10⁻¹⁹, MnS ~10⁻¹³, ZnS ~10⁻²³). In ammoniacal medium [S²⁻] is high enough for these but Group V carbonates stay soluble — the group basis.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- H₂S source
- Fume cupboard
- Filter paper + funnel
Chemical Reagents
- Mixture (Co²⁺, Ni²⁺, Mn²⁺, Zn²⁺)
- Aqueous NH₃ (~2 M)
- H₂S gas
Step-by-Step Practical Procedure
- Make the Group III filtrate ammoniacal with NH₃.
- Pass H₂S in the fume cupboard: sulphides precipitate.
- Filter quickly (MnS oxidises in air to brown MnO(OH)).
- Note colours: black (Co/Ni), buff (Mn), white (Zn).
- Keep the precipitate moist for the next separation.
Observations & Expected Results
Black CoS/NiS, flesh-coloured MnS (darkens in air), white ZnS.
Worked Stoichiometric Calculations
Problem: Typical Ksp(MnS) ~3×10⁻¹³. In ammoniacal H₂S, [S²⁻] ~0.1 M. What [Mn²⁺] precipitates?
Working: [Mn²⁺] = 3×10⁻¹³/0.1 = 3×10⁻¹² M — essentially complete precipitation.
Safety Precautions & Hazard Control
- H₂S — fume cupboard only.
- MnS oxidises fast — work promptly.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Sulphide precipitates to heavy-metal waste (cobalt/nickel toxic).
Viva Voce Oral Defense Questions & Answers
Q: Why must the solution be ammoniacal, not acidic?
A: High [S²⁻] is needed since Group IV sulphides have larger Ksp than Group II sulphides.
Q: Why does MnS darken on the filter paper?
A: Air oxidation: MnS → MnO(OH)/MnO₂ (brown).