CHEMVEN

Confirmatory Test for Aluminium: Lake Test and Thénard's Blue

Confirm Al³⁺ by the alizarin lake test and the cobalt-nitrate blue ash.

Level: UniversitySafety: Needs supervisionTime: 40 min
Aim of Experiment: Confirm Al³⁺ by the alizarin lake test and the cobalt-nitrate blue ash.

Theoretical Foundations

Al(OH)₃ adsorbs the dye alizarin to give a red 'lake' on the white precipitate — a classic adsorption indicator test. In the dry test, heating Al₂O₃ with Co(NO₃)₂ gives blue cobalt aluminate, CoAl₂O₄ (Thénard's blue). Al³⁺ also dissolves in excess NaOH as [Al(OH)₄]⁻, separating it from Fe³⁺.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Filter paper
  • Bunsen burner
  • Charcoal block
  • Dropper

Chemical Reagents

  • Aluminium sulphate (~0.1 M)
  • Aqueous NH₃
  • Alizarin reagent (or alizarin S)
  • Cobalt nitrate solution
  • Sodium hydroxide (~2 M)

Step-by-Step Practical Procedure

  1. Precipitate Al(OH)₃ with NH₃ (white, gelatinous).
  2. Add alizarin and re-precipitate: red lake on the white hydroxide.
  3. Separately, add excess NaOH to Al³⁺: precipitate dissolves as [Al(OH)₄]⁻.
  4. Dry test: moisten Al₂O₃ residue with Co(NO₃)₂, heat on charcoal — blue mass (Thénard's blue).

Observations & Expected Results

Red lake; dissolution in excess NaOH; blue ash with cobalt nitrate.

Worked Stoichiometric Calculations

Problem: Al(OH)₃ is amphoteric. Write both dissolution equations.

Working: Acid: Al(OH)₃ + 3H⁺ → Al³⁺ + 3H₂O. Base: Al(OH)₃ + OH⁻ → [Al(OH)₄]⁻.

Safety Precautions & Hazard Control

  • Burner safety; hot charcoal — tongs.
  • Cobalt nitrate is toxic — small amounts.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Aluminium residues to chemical waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is the lake test done on the precipitate, not in solution?

A: The dye adsorbs onto solid Al(OH)₃ — it is a surface phenomenon, so the precipitate must be present.

Q: How does excess NaOH separate Al³⁺ from Fe³⁺?

A: Fe(OH)₃ is not amphoteric and stays precipitated; [Al(OH)₄]⁻ stays in solution.