Confirmatory Test for Aluminium: Lake Test and Thénard's Blue
Confirm Al³⁺ by the alizarin lake test and the cobalt-nitrate blue ash.
Theoretical Foundations
Al(OH)₃ adsorbs the dye alizarin to give a red 'lake' on the white precipitate — a classic adsorption indicator test. In the dry test, heating Al₂O₃ with Co(NO₃)₂ gives blue cobalt aluminate, CoAl₂O₄ (Thénard's blue). Al³⁺ also dissolves in excess NaOH as [Al(OH)₄]⁻, separating it from Fe³⁺.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Filter paper
- Bunsen burner
- Charcoal block
- Dropper
Chemical Reagents
- Aluminium sulphate (~0.1 M)
- Aqueous NH₃
- Alizarin reagent (or alizarin S)
- Cobalt nitrate solution
- Sodium hydroxide (~2 M)
Step-by-Step Practical Procedure
- Precipitate Al(OH)₃ with NH₃ (white, gelatinous).
- Add alizarin and re-precipitate: red lake on the white hydroxide.
- Separately, add excess NaOH to Al³⁺: precipitate dissolves as [Al(OH)₄]⁻.
- Dry test: moisten Al₂O₃ residue with Co(NO₃)₂, heat on charcoal — blue mass (Thénard's blue).
Observations & Expected Results
Red lake; dissolution in excess NaOH; blue ash with cobalt nitrate.
Worked Stoichiometric Calculations
Problem: Al(OH)₃ is amphoteric. Write both dissolution equations.
Working: Acid: Al(OH)₃ + 3H⁺ → Al³⁺ + 3H₂O. Base: Al(OH)₃ + OH⁻ → [Al(OH)₄]⁻.
Safety Precautions & Hazard Control
- Burner safety; hot charcoal — tongs.
- Cobalt nitrate is toxic — small amounts.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Aluminium residues to chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is the lake test done on the precipitate, not in solution?
A: The dye adsorbs onto solid Al(OH)₃ — it is a surface phenomenon, so the precipitate must be present.
Q: How does excess NaOH separate Al³⁺ from Fe³⁺?
A: Fe(OH)₃ is not amphoteric and stays precipitated; [Al(OH)₄]⁻ stays in solution.