Full Group II Mixture Analysis
Analyse an unknown containing Group II cations through the complete IIA/IIB scheme.
Theoretical Foundations
The complete scheme: H₂S in 0.3 M HCl → sulphides; yellow ammonium sulphide split → IIA residue (Cu, Pb, Hg, Bi, Cd) and IIB thiosalts (As, Sb, Sn); HNO₃ work-up of IIA; individual confirmations. Each colour, solubility and complexation step has a thermodynamic (Ksp/complex) basis covered in experiments 008–020.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes (12)
- Water bath
- Filter papers + funnels
- Fume cupboard
- Droppers
Chemical Reagents
- Unknown (Group II cations)
- Dilute HCl
- H₂S source
- Yellow ammonium sulphide
- Aqueous NH₃
- Dilute HNO₃
- K₄[Fe(CN)₆]
- Ammonium molybdate
Step-by-Step Practical Procedure
- Precipitate with H₂S in ~0.3 M HCl; filter and wash.
- Extract with warm yellow ammonium sulphide; filter (IIA residue / IIB filtrate).
- Acidify IIB filtrate: yellow = As/Sn, orange = Sb; confirm each.
- Dissolve IIA residue in dilute HNO₃; black residue = HgS.
- From the nitric filtrate confirm Pb²⁺ (H₂SO₄/K₂CrO₄), Bi³⁺ (dilution), Cu²⁺ (NH₃/K₄[Fe(CN)₆]), Cd²⁺ (CdS).
- Tabulate all results with confirmatory evidence.
Observations & Expected Results
A decision tree of colours and solubilities leading to each cation's confirmation.
Worked Stoichiometric Calculations
Problem: The IIB acidified extract gives only a yellow precipitate. Which cations are possible?
Working: As (As₂S₃) and/or Sn (SnS₂) — Sb is excluded (orange Sb₂S₃ absent).
Safety Precautions & Hazard Control
- Full H₂S, cyanide-free but arsenic/antimony/mercury toxicity — fume cupboard throughout.
- Gloves and eye protection.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Segregate arsenic/mercury waste; neutralise acids.
Viva Voce Oral Defense Questions & Answers
Q: Why is Group II done before Group III?
A: Group II sulphides would otherwise contaminate the Group III hydroxide precipitate.
Q: What is the single most error-prone step?
A: Controlling the HCl concentration — too low precipitates Group IV sulphides too.