Confirmatory Test for Arsenic: Molybdate and the Reinsch Test

Confirm arsenic by ammonium molybdate (yellow arsenomolybdate) and the Reinsch copper-foil test.

Level: UniversitySafety: Advanced lab onlyTime: 50 min
Aim of Experiment: Confirm arsenic by ammonium molybdate (yellow arsenomolybdate) and the Reinsch copper-foil test.

Theoretical Foundations

Arsenate with ammonium molybdate in HNO₃ gives yellow ammonium arsenomolybdate, (NH₄)₃[As(Mo₃O₁₀)₄]. In the Reinsch test, boiling with HCl and copper foil deposits a steel-grey film of elemental As on the copper. Both are classic arsenic confirmations; the Marsh test (arsine mirror) is the ultimate one.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Water bath
  • Copper foil strip
  • Fume cupboard

Chemical Reagents

  • Sodium arsenite/arsenate (~0.05 M)
  • Ammonium molybdate reagent
  • Concentrated HNO₃
  • Concentrated HCl
  • Copper foil

Step-by-Step Practical Procedure

  1. To arsenate solution add conc. HNO₃ and ammonium molybdate; warm: yellow crystalline precipitate.
  2. For Reinsch: boil copper foil in the sample with conc. HCl for 5 min.
  3. Steel-grey deposit on the foil = arsenic.
  4. Wash and dry the foil; heat in a dry tube — garlic-odour sublimate of As₂O₃.

Observations & Expected Results

Yellow arsenomolybdate; steel-grey film on copper; garlic smell on heating the foil.

Worked Stoichiometric Calculations

Problem: The Marsh test converts As to AsH₃. How many moles of AsH₃ from 0.010 mol As₂O₃?

Working: As₂O₃ → 2AsH₃, so 0.020 mol AsH₃ (illustrative stoichiometry).

Safety Precautions & Hazard Control

  • Arsenic compounds are highly toxic — fume cupboard, gloves, minimal quantities.
  • Arsine gas is lethal — never generate it deliberately here.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

All arsenic waste to dedicated toxic heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: How is the molybdate test distinguished from phosphate?

A: Both give yellow precipitates; arsenate's forms only on warming, phosphate's in the cold — and As₂S₃ is yellow, unlike phosphates.

Q: What causes the garlic odour?

A: Volatile As₂O₃ sublimate on heating the Reinsch foil.