Confirmatory Test for Mercury(II): Stannous Chloride Reduction
Confirm Hg²⁺ by stepwise reduction with SnCl₂: white Hg₂Cl₂ then grey Hg.
Theoretical Foundations
SnCl₂ reduces Hg²⁺ first to white Hg₂Cl₂: 2HgCl₂ + SnCl₂ → Hg₂Cl₂ + SnCl₄; excess SnCl₂ reduces further to grey metallic mercury: Hg₂Cl₂ + SnCl₂ → 2Hg + SnCl₄. The white→grey sequence is characteristic of Hg(II).
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Dropper
- Fume cupboard
- Test-tube rack
Chemical Reagents
- Mercury(II) chloride (~0.05 M)
- Stannous chloride (freshly prepared)
- Dilute HCl
Step-by-Step Practical Procedure
- Add a few drops of SnCl₂ to HgCl₂ solution: white precipitate of Hg₂Cl₂.
- Add excess SnCl₂: the white precipitate turns grey (metallic Hg).
- Note the colour sequence carefully — it is the confirmatory observation.
- Run a reagent blank without Hg²⁺ to confirm the reagents give no precipitate.
Observations & Expected Results
White silky precipitate → grey metallic deposit with excess reductant.
Worked Stoichiometric Calculations
Problem: In the first step, what is the mole ratio HgCl₂ : SnCl₂?
Working: 2:1 — 2HgCl₂ + SnCl₂ → Hg₂Cl₂ + SnCl₄.
Safety Precautions & Hazard Control
- Mercury(II) chloride is very toxic — fume cupboard, gloves.
- Fresh SnCl₂ only.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Mercury waste to the dedicated mercury container.
Viva Voce Oral Defense Questions & Answers
Q: Why must SnCl₂ be fresh?
A: Air oxidises Sn²⁺ to Sn⁴⁺, which cannot reduce Hg²⁺.
Q: How does this differ from the Hg(I) ammonia test?
A: That test blackens via disproportionation; this one reduces stepwise white→grey, specific to Hg(II) salts.