Sacrificial Anodes: Zinc Protecting Iron in Salt Water
To demonstrate cathodic protection by coupling iron to a zinc sacrificial anode in salt water.
Theoretical Foundations
When zinc and iron are in electrical contact in an electrolyte, they form a galvanic cell. Zinc (E° = −0.76 V) is the anode and dissolves (Zn → Zn²⁺ + 2e⁻), supplying electrons that keep iron (E° = −0.44 V) cathodic so it cannot oxidize. The zinc is 'sacrificed' and must be replaced periodically — the principle protecting ship hulls and pipelines.
Required Apparatus & Chemicals
Laboratory Apparatus
- 2 beakers
- 2 iron nails
- Zinc strip
- Copper wire
- Salt water (3.5% NaCl)
Chemical Reagents
- Sodium chloride solution, 3.5% (about 400 mL)
- Iron nails (2)
- Zinc strip (about 5 g)
Step-by-Step Practical Procedure
- Place one nail alone in beaker 1 with salt water (control).
- Wrap the second nail tightly with zinc strip, join with copper wire, and place in beaker 2.
- Ensure good metal-to-metal contact between zinc and iron.
- Leave both for 7 days.
- Inspect daily for rust on the iron and white corrosion product on the zinc.
- Weigh the zinc strip before and after to estimate metal sacrificed.
Observations & Expected Results
The unprotected nail rusts heavily; the coupled nail stays bright while the zinc develops a white crust of zinc corrosion products and loses mass.
Worked Stoichiometric Calculations
Problem: The zinc strip loses 0.65 g in 7 days. How many moles of electrons did it supply? (Zn = 65.38)
Working: Moles Zn = 0.65/65.38 = 0.00994 mol. Each Zn gives 2e⁻, so electrons = 0.0199 mol ≈ 0.020 mol of electrons.
Safety Precautions & Hazard Control
- Ensure the wire connections are above the waterline to avoid extra couples.
- Salt water is low hazard.
- Dry hands before handling electrical connections if a meter is used.
Waste Disposal Protocol
Salt water down the drain; the zinc strip and nails go in metal recycling.
Viva Voce Oral Defense Questions & Answers
Q: Why is the zinc called 'sacrificial'?
A: It corrodes away (is sacrificed) to keep the iron cathodic and uncorroded.
Q: What happens when all the zinc is consumed?
A: Protection stops and the iron begins to rust — anodes must be replaced.
Q: Name two real applications.
A: Ship hulls, underground pipelines, water heaters, offshore platforms.