Chelation Therapy Model: EDTA vs Dimercaprol for Lead(II)
To compare EDTA and dimercaprol (BAL) as chelators for Pb²⁺ (model study).
Theoretical Foundations
Lead poisoning is treated with chelators: CaNa₂EDTA (log K Pb–EDTA ≈ 18) or dimercaprol (dithiol, soft S-donors binding soft Pb²⁺). In this model, Pb²⁺ is precipitated as PbS; adding each chelator redissolves different amounts — comparing hard (EDTA) vs soft (thiol) chelation of a soft-ish metal.
Required Apparatus & Chemicals
Laboratory Apparatus
- 3 test tubes
- Test tube rack
- Droppers
- Glass rods
- Weighing balance
- pH paper
Chemical Reagents
- Lead(II) nitrate (0.1 M, CAUTION)
- Sodium sulphide (0.1 M)
- EDTA disodium salt (0.1 M)
- Dimercaprol solution (0.05 M, CAUTION)
- Distilled water
Step-by-Step Practical Procedure
- Precipitate PbS in 3 tubes (Pb(NO₃)₂ + Na₂S) — black precipitate.
- Tube 1 (control): add water — no change.
- Tube 2: add EDTA solution — partial dissolution of PbS.
- Tube 3: add dimercaprol — more complete dissolution (soft–soft).
- Compare and discuss HSAB: soft S-donors suit Pb²⁺ best.
Observations & Expected Results
Black PbS dissolves little in water, partially in EDTA, most in dimercaprol — demonstrating HSAB-matched chelation therapy design.
Worked Stoichiometric Calculations
Problem: Ksp(PbS) = 3×10⁻²⁸, Kf(Pb–EDTA) = 10¹⁸. Find K for PbS + EDTA⁴⁻ → [Pb(EDTA)]²⁻ + S²⁻.
Working: K = Ksp × Kf = 3×10⁻²⁸ × 10¹⁸ = 3×10⁻¹⁰ — dissolution limited; thiol chelators do better (higher effective K via softer donors).
Safety Precautions & Hazard Control
- Lead compounds are toxic — gloves, microscale, no ingestion.
- Na₂S releases H₂S with acids — keep neutral/alkaline.
- Dimercaprol — gloves, ventilation.
Waste Disposal Protocol
All lead waste to the lead-designated toxic waste container.
Viva Voce Oral Defense Questions & Answers
Q: What is chelation therapy?
A: Using chelating drugs to bind and excrete toxic metals.
Q: Why dimercaprol for lead?
A: Soft thiol donors match soft Pb²⁺ (HSAB) — stronger binding.
Q: Why CaNa₂EDTA not Na₄EDTA?
A: To avoid stripping Ca²⁺ from blood — calcium salt exchanges Ca for Pb.