Magnetic Titration: Evans NMR Method for [Ni(en)₃]²⁺

To determine the magnetic moment of [Ni(en)₃]²⁺ by the Evans NMR method.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To determine the magnetic moment of [Ni(en)₃]²⁺ by the Evans NMR method.

Theoretical Foundations

The Evans method: a paramagnetic sample shifts the NMR signal of a reference (t-butanol) proportional to its susceptibility: χM = (3Δf)/(4πf·m) + corrections. From χM, μeff = 2.828√(χM·T). For [Ni(en)₃]²⁺ (d⁸, n = 2), expect ~3.0 BM. No Gouy balance needed — just an NMR spectrometer.

Required Apparatus & Chemicals

Laboratory Apparatus

  • NMR spectrometer (60 MHz+)
  • NMR tubes (one with capillary insert)
  • Weighing balance
  • Volumetric flasks
  • Pipettes

Chemical Reagents

  • [Ni(en)₃]Cl₂ (~0.5 g, prepared)
  • Deuterium oxide (D₂O)
  • t-Butanol (reference)
  • Distilled water

Step-by-Step Practical Procedure

  1. Prepare 0.05 M [Ni(en)₃]Cl₂ in D₂O with 1% t-butanol.
  2. Fill an NMR tube; insert a sealed capillary of pure t-butanol/D₂O.
  3. Record ¹H NMR — two t-butanol singlets appear (shifted + unshifted).
  4. Measure Δf (Hz) between them; compute mass susceptibility.
  5. Calculate χM and μeff; compare with 2.83 BM spin-only.

Observations & Expected Results

t-Butanol peaks separated by ~20–40 Hz; computed μeff ≈ 3.0–3.2 BM — confirming 2 unpaired electrons (d⁸ octahedral).

Worked Stoichiometric Calculations

Problem: Δf = 30 Hz at 400 MHz, m = 0.05 g/mL. Estimate χg (simplified: χg = 3Δf/(4π·f·m)).

Working: χg = 3×30/(4π × 4×10⁸ × 0.05) = 90/(2.51×10⁸) = 3.58×10⁻⁷ cm³/g (order of magnitude; full Evans equation adds density/diamagnetic corrections).

Safety Precautions & Hazard Control

  • D₂O — keep capped (exchanges with moisture).
  • NMR tubes are fragile.
  • Nickel — gloves.

Waste Disposal Protocol

Nickel/D₂O waste to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: What is the Evans method?

A: Measuring paramagnetic susceptibility from the NMR shift of a reference in the sample vs a capillary.

Q: Why t-butanol?

A: Sharp singlet, inert, water-soluble reference.

Q: Why is observed μ > spin-only?

A: Orbital contribution in octahedral Ni(II).