Magnetic Titration: Evans NMR Method for [Ni(en)₃]²⁺
To determine the magnetic moment of [Ni(en)₃]²⁺ by the Evans NMR method.
Theoretical Foundations
The Evans method: a paramagnetic sample shifts the NMR signal of a reference (t-butanol) proportional to its susceptibility: χM = (3Δf)/(4πf·m) + corrections. From χM, μeff = 2.828√(χM·T). For [Ni(en)₃]²⁺ (d⁸, n = 2), expect ~3.0 BM. No Gouy balance needed — just an NMR spectrometer.
Required Apparatus & Chemicals
Laboratory Apparatus
- NMR spectrometer (60 MHz+)
- NMR tubes (one with capillary insert)
- Weighing balance
- Volumetric flasks
- Pipettes
Chemical Reagents
- [Ni(en)₃]Cl₂ (~0.5 g, prepared)
- Deuterium oxide (D₂O)
- t-Butanol (reference)
- Distilled water
Step-by-Step Practical Procedure
- Prepare 0.05 M [Ni(en)₃]Cl₂ in D₂O with 1% t-butanol.
- Fill an NMR tube; insert a sealed capillary of pure t-butanol/D₂O.
- Record ¹H NMR — two t-butanol singlets appear (shifted + unshifted).
- Measure Δf (Hz) between them; compute mass susceptibility.
- Calculate χM and μeff; compare with 2.83 BM spin-only.
Observations & Expected Results
t-Butanol peaks separated by ~20–40 Hz; computed μeff ≈ 3.0–3.2 BM — confirming 2 unpaired electrons (d⁸ octahedral).
Worked Stoichiometric Calculations
Problem: Δf = 30 Hz at 400 MHz, m = 0.05 g/mL. Estimate χg (simplified: χg = 3Δf/(4π·f·m)).
Working: χg = 3×30/(4π × 4×10⁸ × 0.05) = 90/(2.51×10⁸) = 3.58×10⁻⁷ cm³/g (order of magnitude; full Evans equation adds density/diamagnetic corrections).
Safety Precautions & Hazard Control
- D₂O — keep capped (exchanges with moisture).
- NMR tubes are fragile.
- Nickel — gloves.
Waste Disposal Protocol
Nickel/D₂O waste to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the Evans method?
A: Measuring paramagnetic susceptibility from the NMR shift of a reference in the sample vs a capillary.
Q: Why t-butanol?
A: Sharp singlet, inert, water-soluble reference.
Q: Why is observed μ > spin-only?
A: Orbital contribution in octahedral Ni(II).