Preparation of Tris(oxalato)cobaltate(III): K₃[Co(C₂O₄)₃]·3H₂O
To prepare deep-green K₃[Co(C₂O₄)₃] by oxidation of Co(II) oxalate.
Theoretical Foundations
Co(II) oxalate is oxidised by H₂O₂ or PbO₂ in potassium oxalate solution to give [Co(C₂O₄)₃]³⁻ — low-spin d⁶, octahedral, chiral (Δ/Λ). The reaction: 2CoC₂O₄ + 4K₂C₂O₄ + H₂O₂ → 2K₃[Co(C₂O₄)₃] + 2KOH. The deep-green complex is a classic Werner compound.
Required Apparatus & Chemicals
Laboratory Apparatus
- 500 mL beaker
- Glass rod
- Buchner funnel
- Filter flask
- Weighing balance
- Hot plate
- Ice bath
- Fume hood
Chemical Reagents
- Cobalt(II) chloride hexahydrate (~6 g)
- Oxalic acid dihydrate (~6.3 g)
- Potassium oxalate monohydrate (~9 g)
- Hydrogen peroxide (30%, ~10 mL)
- Ethanol
- Distilled water
Step-by-Step Practical Procedure
- Precipitate CoC₂O₄: mix CoCl₂ solution with oxalic acid solution; filter the pink precipitate.
- Dissolve 9 g potassium oxalate in 40 mL warm water; add the moist CoC₂O₄.
- Add 10 mL 30% H₂O₂ dropwise with stirring — pink turns deep green.
- Heat 15 min at 60 °C; cool in ice.
- Filter the dark-green crystals; wash with ethanol; dry in the dark.
Observations & Expected Results
Pink CoC₂O₄ oxidises to a deep-green solution; dark-green crystals of K₃[Co(C₂O₄)₃]·3H₂O separate. Yield ~6–7 g (~60%).
Worked Stoichiometric Calculations
Problem: Calculate the CFSE of [Co(C₂O₄)₃]³⁻.
Working: Low-spin d⁶: t₂g⁶ → CFSE = 6×(−0.4Δ₀) = −2.4Δ₀ (plus 2P pairing).
Safety Precautions & Hazard Control
- 30% H₂O₂ — strong oxidiser, gloves, goggles.
- Oxalic acid — toxic, gloves.
- Cobalt waste collected.
Waste Disposal Protocol
Cobalt/oxalate waste to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is oxidation needed?
A: Co(II) oxalate must be oxidised to Co(III), which forms the stable chelate.
Q: Is the complex chiral?
A: Yes — D₃ propeller, Δ/Λ enantiomers (racemic product).
Q: What is its magnetic behaviour?
A: Diamagnetic — low-spin d⁶, all paired.