Preparation of Dicyanoargentate(I): K[Ag(CN)₂] (Silver Plating Salt)
To prepare K[Ag(CN)₂], the classic silver electroplating salt.
Theoretical Foundations
AgCN dissolves in KCN: AgCN + CN⁻ → [Ag(CN)₂]⁻ (linear, d¹⁰). The complex lowers free Ag⁺ to ~10⁻²¹ M, giving smooth, adherent electroplated silver — the basis of silver plating baths. Formation constant β₂ ≈ 10²¹.
Required Apparatus & Chemicals
Laboratory Apparatus
- 250 mL beaker
- Glass rod
- Buchner funnel
- Filter flask
- Weighing balance
- Fume hood
- Electroplating cell (optional)
Chemical Reagents
- Silver nitrate (~3.4 g)
- Potassium cyanide (~3 g, CAUTION — teacher dispenses)
- Sodium carbonate
- Distilled water
Step-by-Step Practical Procedure
- Precipitate AgCN: add KCN solution to AgNO₃ until precipitation is complete.
- Add excess KCN with stirring — precipitate redissolves as K[Ag(CN)₂].
- Filter, concentrate the filtrate, cool — colourless crystals of K[Ag(CN)₂] separate.
- Filter, dry in a desiccator.
- Optional: electroplate a copper coin from the solution at low current — bright silver deposit.
Observations & Expected Results
White AgCN dissolves in excess cyanide; colourless crystals of K[Ag(CN)₂] form; electroplating gives a bright adherent silver layer.
Worked Stoichiometric Calculations
Problem: β₂ = 1×10²¹. In 0.1 M [Ag(CN)₂]⁻ with 0.1 M excess CN⁻, find free [Ag⁺].
Working: [Ag⁺] = [complex]/(β₂[CN⁻]²) = 0.1/(10²¹ × 0.01) = 1×10⁻²⁰ M.
Safety Precautions & Hazard Control
- KCN is lethal — teacher only, fume hood, gloves, never with acids.
- All cyanide waste to the cyanide bottle.
- Electroplating — low voltage only.
Waste Disposal Protocol
Every cyanide-containing drop to the labelled cyanide waste container.
Viva Voce Oral Defense Questions & Answers
Q: Why is the complex used for plating?
A: Very low free Ag⁺ gives slow, uniform deposition — smooth adherent plate.
Q: What is the geometry?
A: Linear [Ag(CN)₂]⁻.
Q: What is the EAN of Ag?
A: 47 − 1 + 4 = 50.