CHEMVEN

Preparation of Potassium Tetraiodidomercurate(II): Nessler's Reagent K₂[HgI₄]

To prepare Nessler's reagent (K₂[HgI₄] in KOH) and test for ammonia.

Level: UniversitySafety: Advanced lab onlyTime: 45 min
Aim of Experiment: To prepare Nessler's reagent (K₂[HgI₄] in KOH) and test for ammonia.

Theoretical Foundations

Hg(II) (d¹⁰) with excess iodide forms the tetrahedral complex [HgI₄]²⁻. In alkaline solution (Nessler's reagent), ammonia gives the brown precipitate of Millon's base iodide: 2K₂[HgI₄] + NH₃ + 3KOH → [Hg₂N]I·H₂O (brown) + 7KI + 2H₂O. This is the classic sensitive test for NH₃/NH₄⁺.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 100 mL beaker
  • Glass rod
  • Weighing balance
  • Test tubes
  • Droppers
  • Fume hood

Chemical Reagents

  • Mercury(II) iodide (~4.5 g)
  • Potassium iodide (~3.3 g)
  • Potassium hydroxide (6 M, ~30 mL)
  • Ammonium chloride solution (test)
  • Distilled water

Step-by-Step Practical Procedure

  1. Dissolve 3.3 g KI in 10 mL water; add 4.5 g HgI₂ with stirring — red solid dissolves giving colourless K₂[HgI₄] solution.
  2. Dilute to 30 mL, then add 30 mL of 6 M KOH with stirring — Nessler's reagent.
  3. Store in a brown bottle.
  4. Test: add 2 drops to 5 mL dilute NH₄Cl solution — yellow-brown colour/precipitate confirms NH₃.
  5. Compare with a blank (distilled water) — no colour.

Observations & Expected Results

Colourless K₂[HgI₄]/KOH reagent; with NH₄⁺ it gives a yellow to brown colour/precipitate (Millon's base); blank stays colourless.

Worked Stoichiometric Calculations

Problem: Calculate the EAN of Hg in [HgI₄]²⁻.

Working: Hg atomic number 80. Hg(II): 80 − 2 = 78; 4 I⁻ donate 8 → 86 = Rn.

Safety Precautions & Hazard Control

  • Mercury compounds are highly toxic — gloves, fume hood, no skin contact, collect all waste.
  • KOH is corrosive.
  • Never pour mercury waste down the drain.

Waste Disposal Protocol

All mercury-containing waste to the dedicated mercury waste container.

Viva Voce Oral Defense Questions & Answers

Q: What is the geometry of [HgI₄]²⁻?

A: Tetrahedral.

Q: What causes the brown colour in the test?

A: Formation of the iodide of Millon's base, [Hg₂N]I·H₂O.

Q: Why must mercury waste be segregated?

A: Mercury is a cumulative neurotoxin; environmental regulations require special disposal.

← Back to Experiments Directory