Theoretical Foundations

Fe(III) is d⁵. With weak-field H₂O it is high-spin (t₂g³ eg², n = 5, μ ≈ 5.92 BM); with strong-field CN⁻ it is low-spin (t₂g⁵, n = 1, μ ≈ 2.3 BM with orbital contribution). The Gouy balance measures the force on a sample in a magnetic field, giving mass susceptibility χg, from which μeff = 2.828√(χM·T) is calculated.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Gouy balance (electromagnet + analytical balance)
  • Gouy tubes
  • Weighing balance
  • Spatula
  • Test tubes

Chemical Reagents

  • Ammonium iron(III) sulphate (ferric alum, ~5 g)
  • Potassium hexacyanoferrate(III), K₃[Fe(CN)₆] (~3 g)
  • Calibrant: Hg[Co(SCN)₄] (known χg)
  • Distilled water

Step-by-Step Practical Procedure

  1. Pack a Gouy tube uniformly with dry ferric alum; weigh with field off and on.
  2. Repeat with K₃[Fe(CN)₆] and with the calibrant.
  3. Calculate mass susceptibility χg from Δw using the calibrant constant.
  4. Convert to molar susceptibility χM and compute μeff = 2.828√(χM·T).
  5. Compare with spin-only values: 5.92 BM (n=5) vs 1.73 BM (n=1).

Observations & Expected Results

Ferric alum: μeff ≈ 5.9 BM (high-spin d⁵, 5 unpaired e⁻). K₃[Fe(CN)₆]: μeff ≈ 2.3 BM (low-spin d⁵, 1 unpaired e⁻) — confirming weak-field H₂O vs strong-field CN⁻.

Worked Stoichiometric Calculations

Problem: χM = 1.50×10⁻² cm³/mol at 300 K. Calculate μeff and deduce unpaired electrons.

Working: μeff = 2.828√(1.50×10⁻² × 300) = 2.828√4.5 = 6.00 BM ≈ 5.92 → n = 5 unpaired electrons (high spin).

Safety Precautions & Hazard Control

  • Pack tubes uniformly — air gaps cause errors.
  • Keep the electromagnet from overheating.
  • Handle the analytical balance with care.

Waste Disposal Protocol

Iron salts are low hazard; wash to drain with plenty of water.

Viva Voce Oral Defense Questions & Answers

Q: What is the spin-only formula?

A: μ = √[n(n+2)] BM.

Q: Why does CN⁻ give low spin?

A: Strong-field ligand: Δ₀ > pairing energy, electrons pair in t₂g.

Q: What causes the slightly high value for K₃[Fe(CN)₆]?

A: Orbital contribution to the magnetic moment in t₂g⁵.