Quantitative Estimation of RNA by Orcinol
To estimate RNA in yeast extract using the orcinol method with a standard curve.
Theoretical Foundations
The green orcinol-furfural complex (660 nm) is proportional to ribose, hence RNA, over the microgram range; yeast RNA standards calibrate the assay.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer
- Boiling water bath
- Test tubes
- Pipettes
Chemical Reagents
- Orcinol reagent
- Yeast RNA standards (0-100 ug/mL)
- Yeast extract sample
- Distilled water
Step-by-Step Practical Procedure
- Mix 1 mL of each standard and diluted sample with 2 mL orcinol reagent.
- Heat exactly 5 minutes; cool rapidly.
- Read A660 against the blank.
- Construct the standard curve and read the sample RNA.
- Correct for dilution.
Observations & Expected Results
A graded green series; the sample reading interpolates cleanly on the curve.
Worked Stoichiometric Calculations
Problem: Curve: A660 = 0.007 x C (ug/mL). A 1:20 diluted yeast extract gives A = 0.56. Find the extract's RNA in mg/mL.
Working: Diluted C = 0.56/0.007 = 80 ug/mL. Extract = 80 x 20 = 1600 ug/mL = 1.6 mg/mL RNA.
Safety Precautions & Hazard Control
- Time the 5-minute heating exactly.
- Cool rapidly to stop colour development.
- Ventilate HCl fumes.
- Read promptly; colour is not indefinitely stable.
Waste Disposal Protocol
Neutralise and drain with water; bulk collected as chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: Why must DNA be absent or corrected for?
A: DNA gives a small background colour; in mixed extracts, DNA is measured separately and its contribution subtracted.
Q: Why is rapid cooling important?
A: It stops the acid-catalysed colour reaction at the same point for standards and samples.