Hanes-Woolf Plot for Km and Vmax Determination
To determine Km and Vmax from a Hanes-Woolf plot ([S]/v vs [S]).
Theoretical Foundations
The Hanes-Woolf transformation, [S]/v = (1/Vmax)[S] + Km/Vmax, plots [S]/v against [S] giving slope 1/Vmax and intercept Km/Vmax. It spreads data more evenly than Lineweaver-Burk and is statistically better behaved, though less familiar.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer
- Water bath
- Cuvettes
- Pipettes
Chemical Reagents
- Substrate series (5-6 concentrations)
- Enzyme (dilute)
- Assay buffer
- Chromogen/stop reagents as needed
Step-by-Step Practical Procedure
- Measure initial rates across the substrate series.
- Compute [S]/v for each.
- Plot [S]/v (y) vs [S] (x).
- Determine slope and intercept by linear fit.
- Calculate Vmax = 1/slope, Km = intercept x Vmax.
- Compare with Eadie-Hofstee results.
Observations & Expected Results
Typical: excellent straight line; Km and Vmax match other linearisations within error.
Worked Stoichiometric Calculations
Problem: Hanes-Woolf fit: slope = 0.50 (micromol/min)-1, intercept = 0.15 mM.(micromol/min)-1. Find Vmax and Km.
Working: Vmax = 1/0.50 = 2.0 micromol/min; Km = 0.15 x 2.0 = 0.30 mM (typical illustrative values).
Safety Precautions & Hazard Control
- Accurate [S] matters (it appears on both axes).
- Use initial rates.
- Include points well above and below Km.
Waste Disposal Protocol
Assay waste per the chromogen used.
Viva Voce Oral Defense Questions & Answers
Q: What are the Hanes-Woolf slope and intercept?
A: Slope = 1/Vmax, intercept = Km/Vmax.
Q: Why is it statistically preferable?
A: [S] (the precise variable) is on the x-axis, spreading errors more evenly.
Q: What does the x-intercept give?
A: -Km.