Protein Estimation by the Lowry Method
To estimate protein by the sensitive Lowry method combining Biuret complexation with Folin-Ciocalteu reduction.
Theoretical Foundations
The Lowry assay has two steps: Cu2+-peptide complex formation in alkali, then reduction of the Folin-Ciocalteu phosphomolybdotungstate reagent by the complex plus tyrosine/tryptophan residues, giving intense blue colour at 750 nm. It is ~100x more sensitive than Biuret but sensitive to many interfering substances.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer (750 nm)
- Test tubes
- Pipettes
- Cuvettes
- Vortex mixer
Chemical Reagents
- BSA standards: 0-0.5 mg/mL
- Lowry reagent A (alkaline copper)
- Folin-Ciocalteu reagent (1 N)
- Unknown protein sample
Step-by-Step Practical Procedure
- Add 5 mL reagent A to 1 mL standard/unknown; stand 10 min.
- Add 0.5 mL Folin reagent rapidly with immediate mixing.
- Stand 30 min for full colour development.
- Read A750.
- Plot the BSA standard curve and read the unknown.
Observations & Expected Results
Typical: deep blue colour proportional to protein; linear range ~0.05-0.5 mg/mL. Unknown falls within the curve.
Worked Stoichiometric Calculations
Problem: Standard curve: A750 = 1.60 x C (mg/mL). Unknown A750 = 0.48. Find concentration.
Working: C = 0.48/1.60 = 0.30 mg/mL (typical illustrative value).
Safety Precautions & Hazard Control
- Add Folin reagent quickly with instant mixing; timing matters.
- Folin reagent is acidic and corrosive.
- Avoid detergents, reducing agents and Tris in samples (they interfere).
Waste Disposal Protocol
Molybdenum/tungsten waste: collect as heavy-metal aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is Lowry more sensitive than Biuret?
A: Signal amplification: Folin reduction by Tyr/Trp adds to the copper-peptide colour.
Q: Name two interferents in the Lowry assay.
A: Detergents (SDS), reducing agents (DTT, mercaptoethanol), Tris buffer, EDTA.
Q: At what wavelength is Lowry read?
A: 750 nm (typical).