Corrosion Rate by Weight Loss (Coupons)
To determine the corrosion rate of mild steel in acid and salt media by weight loss.
Theoretical Foundations
Clean, weighed steel coupons are immersed in corrosive media for a fixed time; the mass loss gives the average corrosion rate: mpy = (534 x loss in mg) / (density x area in sq.in x time in hours). Comparing media and inhibitor doses quantifies corrosivity and inhibitor efficiency, the basis of materials selection.
Required Apparatus & Chemicals
Laboratory Apparatus
- Glass jars
- Analytical balance
- Vernier caliper
- Steel coupons
- Water bath (optional)
Chemical Reagents
- 1 N hydrochloric acid
- 3.5% sodium chloride solution
- Corrosion inhibitor (e.g. sodium nitrite)
- Acetone
- Inhibited cleaning acid
Step-by-Step Practical Procedure
- Degrease coupons with acetone, dry, weigh (W1), and measure dimensions.
- Immerse triplicate coupons in each medium: HCl, salt water, salt water + inhibitor.
- Keep 7 days at room temperature, topping up evaporation.
- Remove, clean off corrosion products in inhibited acid, rinse, dry and weigh (W2).
- Calculate mpy for each medium and inhibitor efficiency % = (uninhibited - inhibited) x 100 / uninhibited.
Observations & Expected Results
Steel in 1 N HCl loses visibly with hydrogen bubbling (hundreds of mpy); in salt water it rusts brown (tens of mpy); inhibitor cuts the loss sharply.
Worked Stoichiometric Calculations
Problem: A coupon (area 5 sq.in, density 7.86 g/cc) lost 250 mg in 168 hours. Calculate the corrosion rate in mpy.
Working: mpy = 534 x 250/(7.86 x 5 x 168) = 133500/6602.4 = 20.2 mpy, a moderate rate for salt water.
Safety Precautions & Hazard Control
- Weigh coupons to 0.1 mg; small errors dominate.
- Clean corrosion products without attacking base metal (use inhibited acid).
- Keep immersion times identical.
- Handle HCl with gloves and goggles.
Waste Disposal Protocol
Acid media are neutralised before disposal; coupons go to metal waste.
Viva Voce Oral Defense Questions & Answers
Q: What is mpy?
A: Mils per year: thousandths of an inch of metal lost per year, the standard engineering corrosion rate unit.
Q: How do inhibitors work?
A: They adsorb on the metal surface, blocking anodic or cathodic sites and slowing the electrochemical corrosion reactions.