Chemical Oxygen Demand (COD) of Effluent

To determine the COD of an industrial effluent by dichromate reflux.

Level: UniversitySafety: Advanced lab onlyTime: 3 h
Aim of Experiment: To determine the COD of an industrial effluent by dichromate reflux.

Theoretical Foundations

COD measures nearly all oxidisable matter (biodegradable plus non-biodegradable) using hot acidic potassium dichromate with silver sulphate catalyst. The sample is refluxed 2 hours; unused dichromate is back-titrated with ferrous ammonium sulphate using ferroin indicator. COD is always equal to or higher than BOD.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Reflux assembly
  • Burette
  • Pipette
  • Heating mantle

Chemical Reagents

  • Effluent sample (20 mL)
  • 0.25 N potassium dichromate
  • Concentrated sulphuric acid with silver sulphate
  • 0.1 N ferrous ammonium sulphate
  • Ferroin indicator
  • Mercuric sulphate (chloride mask)

Step-by-Step Practical Procedure

  1. Pipette 20 mL sample into the reflux flask with mercuric sulphate.
  2. Add 10 mL 0.25 N dichromate and 30 mL sulphuric acid-silver sulphate slowly with cooling.
  3. Reflux gently for 2 hours.
  4. Cool, dilute, add ferroin, and titrate with 0.1 N FAS to the red-brown end point.
  5. Run a blank identically.
  6. Calculate COD = (blank - sample) x N x 8000 / sample volume.

Observations & Expected Results

Textile effluents show COD 500-2000 mg/L; the reflux turns from orange (excess dichromate) toward green as organics oxidise.

Worked Stoichiometric Calculations

Problem: 20 mL effluent: blank 24.0 mL, sample 10.5 mL of 0.1 N FAS. Calculate the COD.

Working: COD = (24.0 - 10.5) x 0.1 x 8000/20 = 13.5 x 40 = 540 mg/L.

Safety Precautions & Hazard Control

  • Add acid slowly; the mixing is strongly exothermic.
  • Reflux the full 2 hours for complete oxidation.
  • Mercuric sulphate masks chloride, which otherwise inflates COD.
  • Handle hot concentrated acid with care.

Waste Disposal Protocol

Chromium-containing residues go to the heavy-metal waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is COD higher than BOD?

A: Dichromate oxidises non-biodegradable organics that microbes cannot, so COD captures the total oxidisable load.

Q: What does silver sulphate do?

A: It catalyses the oxidation of straight-chain organics like acetic acid that dichromate alone oxidises slowly.