Breakpoint Chlorination of Water
To determine the breakpoint chlorine dose for a water sample.
Theoretical Foundations
Added chlorine first forms chloramines with ammonia (combined residual), then oxidises them with a falling residual, until the breakpoint where all ammonia is destroyed. Beyond it, free chlorine residual rises linearly. Dosing just past the breakpoint guarantees disinfection with minimum taste. Residuals are measured by the DPD or iodometric method across graded doses.
Required Apparatus & Chemicals
Laboratory Apparatus
- Brown bottles (10)
- Burette
- Pipettes
- Comparator / titration setup
Chemical Reagents
- Water sample containing ammonia
- Chlorine solution (sodium hypochlorite, standardised)
- DPD reagent or KI + thiosulphate
- Starch indicator
Step-by-Step Practical Procedure
- Add graded chlorine doses (0-10 mg/L) to ten bottles of the sample.
- Keep in the dark for 30 minutes contact time.
- Measure residual chlorine in each by DPD colour or iodometric titration.
- Plot residual vs dose.
- Locate the breakpoint (the dip minimum) and the free-residual line beyond it.
- Report the breakpoint dose.
Observations & Expected Results
Residual rises, dips sharply at the breakpoint (around 7-8 mg/L for 1 mg/L ammonia), then climbs steadily as free chlorine.
Worked Stoichiometric Calculations
Problem: Water contains 0.5 mg/L ammonia-nitrogen. The theoretical breakpoint is 7.6 times the ammonia-N. Calculate it.
Working: Breakpoint = 7.6 x 0.5 = 3.8 mg/L chlorine. Dosing slightly above this ensures free residual disinfection.
Safety Precautions & Hazard Control
- Keep bottles in the dark; light destroys chlorine.
- Standardise the hypochlorite the same day.
- Allow the full 30 minutes contact.
- Work in ventilated area; chlorine irritates.
Waste Disposal Protocol
Dechlorinate samples with thiosulphate before drain disposal.
Viva Voce Oral Defense Questions & Answers
Q: What is combined residual chlorine?
A: Chlorine bound as chloramines (with ammonia) or organochloramines; it disinfects weakly and causes chlorine taste.
Q: Why dose past the breakpoint?
A: To destroy ammonia and organics and leave a free chlorine residual that guarantees pathogen kill through the distribution system.