Proximate Analysis of Coal: Moisture
To determine the moisture content of a coal sample (proximate analysis, part 1).
Theoretical Foundations
Moisture in coal is useless weight that evaporates in the furnace, lowering the effective calorific value and causing handling problems. Heating 1 g of air-dried coal at 105-110 C to constant weight drives off moisture; the loss gives the moisture percentage, the first of the four proximate parameters.
Required Apparatus & Chemicals
Laboratory Apparatus
- Hot air oven (108 C)
- Weighing bottles with lids
- Desiccator
- Analytical balance
Chemical Reagents
- Coal sample (1 g, 72-mesh, air-dried)
Step-by-Step Practical Procedure
- Weigh 1 g coal into a tared weighing bottle.
- Heat uncovered at 105-110 C for 1 hour.
- Cover, cool in a desiccator, and weigh.
- Repeat heating for 30 minutes until constant weight.
- Calculate moisture % = loss x 100 / sample weight.
Observations & Expected Results
Air-dried bituminous coal shows 1-5% moisture; lignite may exceed 20%.
Worked Stoichiometric Calculations
Problem: 1.000 g coal weighed 0.972 g after drying. Calculate the moisture content.
Working: Moisture = (1.000 - 0.972)/1.000 x 100 = 2.8%.
Safety Precautions & Hazard Control
- Use the specified 105-110 C range; higher temperatures oxidise the coal.
- Cover the bottle before removing from the oven.
- Cool in a desiccator; hot coal reabsorbs moisture.
- Grind to the specified fineness for representative drying.
Waste Disposal Protocol
Dried coal goes to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the difference between surface and inherent moisture?
A: Surface moisture comes from rain/washing and is easily removed; inherent moisture is held in pores and needs oven drying.
Q: How does moisture affect coal price?
A: Buyers pay for dry coal; high moisture means paying for water and getting less heat.