Loss on Ignition of Cement
To determine the loss on ignition (LOI) of a cement sample.
Theoretical Foundations
LOI measures volatile constituents (combined water, CO2 from carbonation, organic matter) driven off at 900-1000 C. Fresh OPC has LOI under 4-5%; high LOI indicates the cement has absorbed moisture and CO2 during bad storage (pre-hydration and carbonation), which reduces its strength potential.
Required Apparatus & Chemicals
Laboratory Apparatus
- Muffle furnace (1000 C)
- Platinum or silica crucible
- Desiccator
- Analytical balance
- Tongs
Chemical Reagents
- Cement sample (1 g, dried)
Step-by-Step Practical Procedure
- Weigh 1 g cement into a tared crucible.
- Ignite in the muffle furnace at 950 C for 1 hour.
- Cool in a desiccator and weigh.
- Repeat ignition to constant weight.
- Calculate LOI % = loss x 100 / sample weight.
Observations & Expected Results
Fresh cement loses 1-3%; weathered cement may lose over 8% and feels lumpy.
Worked Stoichiometric Calculations
Problem: 1.000 g cement weighed 0.958 g after ignition. Calculate the LOI and comment.
Working: LOI = (1.000 - 0.958)/1.000 x 100 = 4.2%. Just within the usual 5% limit, but the cement should be used promptly.
Safety Precautions & Hazard Control
- Handle the hot crucible only with tongs.
- Cool fully in a desiccator before weighing.
- Ignite to constant weight.
- Keep the furnace ventilated; CO2 evolves during ignition.
Waste Disposal Protocol
Ignited residue goes to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: What gases are lost during ignition?
A: Water from pre-hydrated compounds and carbon dioxide from carbonated lime.
Q: Why does high LOI mean weak cement?
A: It shows part of the cement already reacted with air moisture, leaving less active clinker to hydrate in concrete.