Fineness of Cement by Sieve Analysis
To determine the fineness of cement by dry sieving on a 90-micron sieve.
Theoretical Foundations
Finer cement hydrates faster and develops early strength sooner because of greater surface area. The standard test sieves 100 g of cement through a 90-micron IS sieve; the residue percentage must not exceed 10% for ordinary Portland cement. Excess coarse residue indicates under-ground clinker and slow strength gain.
Required Apparatus & Chemicals
Laboratory Apparatus
- 90-micron IS sieve with lid and pan
- Weighing balance
- Brush
Chemical Reagents
- Cement sample (100 g, oven-dried)
Step-by-Step Practical Procedure
- Weigh 100 g of dry cement.
- Place on the 90-micron sieve, cover, and sieve by gentle shaking for 15 minutes.
- Brush the residue lightly without forcing particles through.
- Weigh the residue retained on the sieve.
- Calculate fineness residue % = residue x 100 / 100.
Observations & Expected Results
Good OPC leaves 5-9% residue; residue above 10% fails the specification.
Worked Stoichiometric Calculations
Problem: 100 g cement left 7.5 g residue on the 90-micron sieve. Does it meet the fineness requirement?
Working: Residue = 7.5%. This is below the 10% maximum, so the cement passes the fineness test.
Safety Precautions & Hazard Control
- Use oven-dry cement; damp cement agglomerates and will not pass.
- Sieve gently; aggressive brushing forces coarse particles through.
- Sieve for the full 15 minutes.
- Work in a dust mask; cement dust irritates lungs.
Waste Disposal Protocol
Cement residue goes to solid waste, not the drain (it can set in pipes).
Viva Voce Oral Defense Questions & Answers
Q: Why does fineness affect strength?
A: Finer particles expose more surface to water, so hydration and early strength development are faster.
Q: What is the Blaine test?
A: An air-permeability method measuring specific surface area (m2/kg); OPC is typically 225-300 m2/kg.