CHEMVEN

Constructed Wetland: Pollutant Removal Demonstration

To demonstrate BOD and nutrient removal by a laboratory-scale constructed wetland.

Level: UniversitySafety: SafeTime: 2 h (plus 7-day operation)
Aim of Experiment: To demonstrate BOD and nutrient removal by a laboratory-scale constructed wetland.

Theoretical Foundations

Constructed wetlands treat wastewater through sedimentation, microbial biofilms on gravel/roots, and plant uptake of nutrients. A bench model (trough with gravel, sand and wetland plants like Typha) fed with synthetic sewage shows BOD, TSS and phosphate reduction over a retention time of days. Removal mechanisms are physical, microbial and plant-based.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Trough/container with gravel and sand media
  • Wetland plants (Typha/Canna)
  • Peristaltic pump or drip feed
  • BOD/TSS/phosphate test sets

Chemical Reagents

  • Starch (synthetic sewage)
  • Urea (synthetic sewage)
  • Potassium dihydrogen phosphate (synthetic sewage)
  • Sodium hypochlorite (sample disinfection)

Step-by-Step Practical Procedure

  1. Set up the trough with graded gravel, sand layer and planted macrophytes.
  2. Feed synthetic sewage at a steady low flow (2-3 day retention).
  3. Allow one week for biofilm establishment.
  4. Sample influent and effluent.
  5. Determine BOD, TSS and phosphate of both.
  6. Calculate percentage removals and discuss mechanisms.

Observations & Expected Results

Effluent clearer with lower odour; BOD removal 70-90%, phosphate 40-60% in a healthy unit.

Worked Stoichiometric Calculations

Problem: Influent BOD 180 mg/L, effluent 25 mg/L; influent P 6 mg/L, effluent 3 mg/L. Calculate removals.

Working: BOD removal = (180-25)/180 x 100 = 86.1%. P removal = (6-3)/6 x 100 = 50%. Good BOD removal; moderate P removal, typical of gravel wetlands without special media.

Safety Precautions & Hazard Control

  • Do not overload the unit; clogging follows.
  • Use non-invasive local plants.
  • Maintain water level below the media surface (subsurface flow).
  • Disinfect effluent samples before disposal.

Waste Disposal Protocol

Effluent: disinfect and drain; spent media to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: Name three removal mechanisms in a wetland.

A: Sedimentation/filtration, microbial degradation in biofilms, and plant uptake of nutrients.

Q: Why keep the water level below the media surface?

A: Subsurface flow avoids mosquito breeding, odours and human contact.

Q: What limits phosphorus removal in wetlands?

A: Finite adsorption capacity of the media; special media (slag, alum sludge) improve it.

← Back to Experiments Directory