Mixed Liquor Suspended Solids (MLSS) in Aeration Tanks

To determine MLSS and MLVSS of activated sludge.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To determine MLSS and MLVSS of activated sludge.

Theoretical Foundations

MLSS is the biomass concentration in the aeration tank (TSS of mixed liquor), typically 2000-4000 mg/L; MLVSS (volatile fraction at 550 C) approximates active biomass, typically 70-80% of MLSS. Operators use MLSS to control the food-to-microorganism (F/M) ratio and sludge age.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Filtration assembly
  • Glass-fibre filters
  • Oven
  • Muffle furnace
  • Analytical balance

Chemical Reagents

  • Distilled water (filter washing)
  • Silica gel (desiccant)
  • Dilute HCl (glassware cleaning)

Step-by-Step Practical Procedure

  1. Weigh a prepared glass-fibre filter.
  2. Filter 50 mL of well-mixed mixed liquor.
  3. Dry at 103 C, cool, weigh: MLSS.
  4. Ignite at 550 C, cool, weigh: loss = MLVSS.
  5. Express both as mg/L.
  6. Compute the volatile fraction and comment on biomass health.

Observations & Expected Results

Brown flocculent biomass on the filter; healthy MLVSS/MLSS ~0.7-0.8.

Worked Stoichiometric Calculations

Problem: 50 mL of mixed liquor gave 150 mg dried solids and 110 mg volatile loss. Calculate MLSS and MLVSS.

Working: MLSS = 150 x 1000/50 = 3000 mg/L. MLVSS = 110 x 1000/50 = 2200 mg/L. Volatile fraction 73% - healthy biomass at a normal operating concentration.

Safety Precautions & Hazard Control

  • Sample from a well-mixed zone of the tank.
  • Filter promptly; biomass respires.
  • Dry/ignite to constant weight.
  • Use a representative volume (25-100 mL).

Waste Disposal Protocol

Dried biomass to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: What is the F/M ratio?

A: Food (BOD load) to microorganism (MLVSS) ratio per day; typically 0.2-0.5 /day for conventional activated sludge.

Q: Why is MLVSS a better biomass measure than MLSS?

A: It excludes inert inorganic solids, approximating the living organic fraction.

Q: What happens if MLSS is too high?

A: Poor settling, oxygen shortage and clarifier overloading; wasting must be increased.