CHEMVEN

Sludge Volume Index: Settleability of Activated Sludge

To determine the sludge volume index (SVI) of activated sludge from an aeration tank.

Level: UniversitySafety: SafeTime: 45 min
Aim of Experiment: To determine the sludge volume index (SVI) of activated sludge from an aeration tank.

Theoretical Foundations

SVI (mL/g) = settled sludge volume in 30 min (mL/L) x 1000 / MLSS (mg/L). It measures sludge settleability: SVI 50-150 mL/g is good; >200 indicates bulking (filamentous growth). It is the key operational control test of activated-sludge plants, paired with MLSS determination.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 1-L graduated cylinder
  • MLSS filtration set
  • Oven
  • Stopwatch

Chemical Reagents

  • No chemicals (settling test)
  • Distilled water (cylinder rinsing)
  • Defoamer (if needed)

Step-by-Step Practical Procedure

  1. Collect a fresh mixed-liquor sample from the aeration tank.
  2. Pour 1 L into the graduated cylinder; start the timer.
  3. Record the sludge blanket volume at 5, 10, 15 and 30 minutes.
  4. Determine MLSS on a separate portion gravimetrically.
  5. Compute SVI = V30 (mL/L) x 1000 / MLSS (mg/L).
  6. Assess settleability and diagnose bulking if high.

Observations & Expected Results

Good sludge: compact blanket, clear supernatant; bulking sludge: fluffy blanket filling most of the cylinder.

Worked Stoichiometric Calculations

Problem: V30 = 280 mL/L, MLSS = 2500 mg/L. Calculate SVI and interpret.

Working: SVI = 280 x 1000 / 2500 = 112 mL/g. Within the good 50-150 range; the sludge settles well.

Safety Precautions & Hazard Control

  • Use a fresh sample; sludge characteristics change quickly.
  • Keep the cylinder still during settling.
  • Stir gently if wall effects appear.
  • Measure MLSS on a well-mixed portion.

Waste Disposal Protocol

Sludge may be returned to the plant or disposed as biological waste.

Viva Voce Oral Defense Questions & Answers

Q: What causes sludge bulking?

A: Excessive filamentous bacteria (from low DO, nutrient deficiency or low F/M) that prevent compact settling.

Q: How is bulking controlled?

A: Chlorination of return sludge, raising DO, adjusting F/M, or adding nutrients.

Q: Why is SVI normalised by MLSS?

A: So that settleability can be compared regardless of the biomass concentration in the tank.

← Back to Experiments Directory