Benzene in Air: Charcoal Tube Sampling Concept
To sample benzene vapours on activated charcoal and understand the desorption-GC analysis.
Theoretical Foundations
Air is drawn through activated charcoal tubes that adsorb benzene; carbon disulphide desorbs it for GC-FID analysis. Indian NAAQS for benzene (annual): 5 ug/m3; WHO states no safe threshold (leukaemogen). Petrol pumps and traffic are the main sources. (GC analysis demonstrated on instructor-provided chromatograms where no GC is available.)
Required Apparatus & Chemicals
Laboratory Apparatus
- Charcoal sorbent tubes
- Calibrated low-flow pump
- Gas chromatograph with FID (demonstration)
- Fume hood
Chemical Reagents
- Carbon disulphide (desorption solvent)
- Benzene stock standard
- Methanol (syringe rinsing)
Step-by-Step Practical Procedure
- Break the ends of a charcoal tube and connect it to the pump.
- Sample at 0.1-0.2 L/min for 2-4 hours at the site.
- Cap the tube immediately after sampling.
- Desorb with 1 mL carbon disulphide in a fume hood.
- Analyse by GC-FID (or interpret provided chromatograms).
- Quantify against benzene standards; divide by air volume.
Observations & Expected Results
Petrol-pump ambient: 10-50 ug/m3 benzene; background: <2 ug/m3.
Worked Stoichiometric Calculations
Problem: Desorption analysis gives 6 ug benzene; air volume 0.048 m3. Calculate benzene and check the 5 ug/m3 annual NAAQS.
Working: Benzene = 6/0.048 = 125 ug/m3. Far above the 5 ug/m3 annual NAAQS; note this is a short-term sample near a source - workers need exposure control and vapour recovery.
Safety Precautions & Hazard Control
- Benzene and CS2 are highly toxic; all handling in a fume hood.
- Do not exceed the tube breakthrough volume.
- Cap tubes immediately to prevent losses.
- Keep pumps calibrated at low flow.
Waste Disposal Protocol
CS2 desorption waste goes to the hazardous organic waste container.
Viva Voce Oral Defense Questions & Answers
Q: Why is activated charcoal used?
A: Its huge surface area strongly adsorbs volatile organics from large air volumes, concentrating them for analysis.
Q: What is breakthrough volume?
A: The air volume at which the analyte starts escaping the back section of the tube - sampling must stay well below it.
Q: Why is there no safe threshold for benzene?
A: It is a genotoxic carcinogen (causes leukaemia); WHO sets no guideline, recommending levels as low as possible.