CHEMVEN

Benzene in Air: Charcoal Tube Sampling Concept

To sample benzene vapours on activated charcoal and understand the desorption-GC analysis.

Level: UniversitySafety: Advanced lab onlyTime: 90 min
Aim of Experiment: To sample benzene vapours on activated charcoal and understand the desorption-GC analysis.

Theoretical Foundations

Air is drawn through activated charcoal tubes that adsorb benzene; carbon disulphide desorbs it for GC-FID analysis. Indian NAAQS for benzene (annual): 5 ug/m3; WHO states no safe threshold (leukaemogen). Petrol pumps and traffic are the main sources. (GC analysis demonstrated on instructor-provided chromatograms where no GC is available.)

Required Apparatus & Chemicals

Laboratory Apparatus

  • Charcoal sorbent tubes
  • Calibrated low-flow pump
  • Gas chromatograph with FID (demonstration)
  • Fume hood

Chemical Reagents

  • Carbon disulphide (desorption solvent)
  • Benzene stock standard
  • Methanol (syringe rinsing)

Step-by-Step Practical Procedure

  1. Break the ends of a charcoal tube and connect it to the pump.
  2. Sample at 0.1-0.2 L/min for 2-4 hours at the site.
  3. Cap the tube immediately after sampling.
  4. Desorb with 1 mL carbon disulphide in a fume hood.
  5. Analyse by GC-FID (or interpret provided chromatograms).
  6. Quantify against benzene standards; divide by air volume.

Observations & Expected Results

Petrol-pump ambient: 10-50 ug/m3 benzene; background: <2 ug/m3.

Worked Stoichiometric Calculations

Problem: Desorption analysis gives 6 ug benzene; air volume 0.048 m3. Calculate benzene and check the 5 ug/m3 annual NAAQS.

Working: Benzene = 6/0.048 = 125 ug/m3. Far above the 5 ug/m3 annual NAAQS; note this is a short-term sample near a source - workers need exposure control and vapour recovery.

Safety Precautions & Hazard Control

  • Benzene and CS2 are highly toxic; all handling in a fume hood.
  • Do not exceed the tube breakthrough volume.
  • Cap tubes immediately to prevent losses.
  • Keep pumps calibrated at low flow.

Waste Disposal Protocol

CS2 desorption waste goes to the hazardous organic waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is activated charcoal used?

A: Its huge surface area strongly adsorbs volatile organics from large air volumes, concentrating them for analysis.

Q: What is breakthrough volume?

A: The air volume at which the analyte starts escaping the back section of the tube - sampling must stay well below it.

Q: Why is there no safe threshold for benzene?

A: It is a genotoxic carcinogen (causes leukaemia); WHO sets no guideline, recommending levels as low as possible.

← Back to Experiments Directory