PM2.5 and PM10: Size-Selective Ambient Sampling

To determine PM10 and PM2.5 concentrations with size-selective inlets and compare with air quality standards.

Level: UniversitySafety: Needs supervisionTime: 2 h (plus 24 h sampling)
Aim of Experiment: To determine PM10 and PM2.5 concentrations with size-selective inlets and compare with air quality standards.

Theoretical Foundations

Cyclone/impactor inlets separate particles by aerodynamic diameter before collection on filters: PM10 inlet passes particles <10 um, PM2.5 inlet <2.5 um. Gravimetric analysis as for SPM gives each fraction. Coarse fraction (PM10-PM2.5) indicates dust/mechanical sources; the fine fraction indicates combustion sources.

Required Apparatus & Chemicals

Laboratory Apparatus

  • PM10 and PM2.5 samplers (or one sampler with interchangeable inlets)
  • Pre-weighed PTFE/quartz filters
  • Microbalance
  • Desiccator

Chemical Reagents

  • Silica gel (desiccant)
  • Distilled water (inlet cleaning)
  • Isopropanol (grease removal)

Step-by-Step Practical Procedure

  1. Condition and weigh filters for both inlets.
  2. Deploy PM10 and PM2.5 samplers side by side for 24 hours.
  3. Record flow rates and sampling duration.
  4. Condition and reweigh filters.
  5. Compute PM10 and PM2.5 in ug/m3.
  6. Calculate the coarse fraction (PM10 - PM2.5) and PM2.5/PM10 ratio; compare with standards.

Observations & Expected Results

Traffic sites: PM2.5/PM10 ratio 0.5-0.7; desert-dust episodes: ratio <0.3 with high coarse fraction.

Worked Stoichiometric Calculations

Problem: PM10 = 132 ug/m3, PM2.5 = 78 ug/m3. Find the coarse fraction and ratio, and check NAAQS (PM10 100, PM2.5 60 ug/m3).

Working: Coarse = 132 - 78 = 54 ug/m3. Ratio PM2.5/PM10 = 78/132 = 0.59, indicating significant combustion sources. Both exceed NAAQS (100 and 60 ug/m3); the air quality is poor.

Safety Precautions & Hazard Control

  • Use the correct inlet for each fraction; do not interchange.
  • Maintain the design flow rate; cut-point depends on it.
  • Avoid filter overloading.
  • Keep inlets clean.

Waste Disposal Protocol

Used filters to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: What does the PM2.5/PM10 ratio tell us?

A: A high ratio (>0.5) points to combustion sources; a low ratio points to mechanical dust sources.

Q: What is aerodynamic diameter?

A: The diameter of a unit-density sphere with the same settling velocity as the particle; it governs sampler cut-points.

Q: Why does the cut-point depend on flow rate?

A: Cyclone/impactor separation is inertial; changing flow changes particle inertia and hence the size collected.