Suspended Particulate Matter in Air: High-Volume Gravimetry

To determine suspended particulate matter (SPM) in ambient air by high-volume sampling and gravimetry.

Level: UniversitySafety: Needs supervisionTime: 2 h (plus 24 h sampling)
Aim of Experiment: To determine suspended particulate matter (SPM) in ambient air by high-volume sampling and gravimetry.

Theoretical Foundations

A high-volume sampler draws air (~1 m3/min) through a pre-weighed glass-fibre filter for 24 hours; the mass gain gives SPM concentration (ug/m3) = mass gain (ug) / air volume (m3). Size-selective inlets give PM10 and PM2.5. Indian NAAQS (24-h): PM10 100 ug/m3, PM2.5 60 ug/m3; WHO 2021 guidelines are stricter (PM10 45, PM2.5 15 ug/m3).

Required Apparatus & Chemicals

Laboratory Apparatus

  • High-volume air sampler with size-selective inlet
  • Glass-fibre filters (pre-weighed)
  • Analytical balance
  • Desiccator
  • Anemometer/flow calibrator

Chemical Reagents

  • Silica gel (desiccant)
  • Distilled water (equipment rinsing)
  • Isopropanol (flow-meter cleaning)

Step-by-Step Practical Procedure

  1. Weigh the filter after conditioning in a desiccator (W1).
  2. Load the filter into the sampler and record the initial flow rate.
  3. Run the sampler for 24 hours at the site.
  4. Record the final flow rate; compute the average flow and total air volume.
  5. Remove, condition and reweigh the filter (W2).
  6. Calculate SPM = (W2 - W1) in ug / volume in m3.
  7. Compare with NAAQS/WHO standards.

Observations & Expected Results

Dusty roadside sites: 150-400 ug/m3 SPM; clean background: <50 ug/m3.

Worked Stoichiometric Calculations

Problem: Filter gain 0.285 g; average flow 1.1 m3/min for 24 h. Calculate SPM and check the PM10 NAAQS of 100 ug/m3.

Working: Volume = 1.1 x 60 x 24 = 1584 m3. Mass = 0.285 g = 285000 ug. SPM = 285000/1584 = 180 ug/m3. Exceeds the 100 ug/m3 PM10 NAAQS (note: this is total SPM; size-selective PM10 would be lower).

Safety Precautions & Hazard Control

  • Condition filters at constant humidity before both weighings.
  • Handle filters with forceps.
  • Calibrate the flow rate; it drops as the filter loads.
  • Protect the sampler from rain ingress.

Waste Disposal Protocol

Used filters go to solid lab waste.

Viva Voce Oral Defense Questions & Answers

Q: Distinguish SPM, PM10 and PM2.5.

A: SPM is total suspended particulates; PM10 is the fraction below 10 um (thoracic) and PM2.5 below 2.5 um (respirable), collected with size-selective inlets.

Q: Why are PM2.5 particles more hazardous?

A: They penetrate deep into the alveoli and enter the bloodstream, causing cardiovascular and respiratory disease.

Q: Why condition filters before weighing?

A: Glass-fibre filters absorb moisture; conditioning at constant humidity gives stable, comparable weights.