Suspended Particulate Matter in Air: High-Volume Gravimetry
To determine suspended particulate matter (SPM) in ambient air by high-volume sampling and gravimetry.
Theoretical Foundations
A high-volume sampler draws air (~1 m3/min) through a pre-weighed glass-fibre filter for 24 hours; the mass gain gives SPM concentration (ug/m3) = mass gain (ug) / air volume (m3). Size-selective inlets give PM10 and PM2.5. Indian NAAQS (24-h): PM10 100 ug/m3, PM2.5 60 ug/m3; WHO 2021 guidelines are stricter (PM10 45, PM2.5 15 ug/m3).
Required Apparatus & Chemicals
Laboratory Apparatus
- High-volume air sampler with size-selective inlet
- Glass-fibre filters (pre-weighed)
- Analytical balance
- Desiccator
- Anemometer/flow calibrator
Chemical Reagents
- Silica gel (desiccant)
- Distilled water (equipment rinsing)
- Isopropanol (flow-meter cleaning)
Step-by-Step Practical Procedure
- Weigh the filter after conditioning in a desiccator (W1).
- Load the filter into the sampler and record the initial flow rate.
- Run the sampler for 24 hours at the site.
- Record the final flow rate; compute the average flow and total air volume.
- Remove, condition and reweigh the filter (W2).
- Calculate SPM = (W2 - W1) in ug / volume in m3.
- Compare with NAAQS/WHO standards.
Observations & Expected Results
Dusty roadside sites: 150-400 ug/m3 SPM; clean background: <50 ug/m3.
Worked Stoichiometric Calculations
Problem: Filter gain 0.285 g; average flow 1.1 m3/min for 24 h. Calculate SPM and check the PM10 NAAQS of 100 ug/m3.
Working: Volume = 1.1 x 60 x 24 = 1584 m3. Mass = 0.285 g = 285000 ug. SPM = 285000/1584 = 180 ug/m3. Exceeds the 100 ug/m3 PM10 NAAQS (note: this is total SPM; size-selective PM10 would be lower).
Safety Precautions & Hazard Control
- Condition filters at constant humidity before both weighings.
- Handle filters with forceps.
- Calibrate the flow rate; it drops as the filter loads.
- Protect the sampler from rain ingress.
Waste Disposal Protocol
Used filters go to solid lab waste.
Viva Voce Oral Defense Questions & Answers
Q: Distinguish SPM, PM10 and PM2.5.
A: SPM is total suspended particulates; PM10 is the fraction below 10 um (thoracic) and PM2.5 below 2.5 um (respirable), collected with size-selective inlets.
Q: Why are PM2.5 particles more hazardous?
A: They penetrate deep into the alveoli and enter the bloodstream, causing cardiovascular and respiratory disease.
Q: Why condition filters before weighing?
A: Glass-fibre filters absorb moisture; conditioning at constant humidity gives stable, comparable weights.