Volatile and Fixed Solids in Wastewater
To determine volatile (organic) and fixed (inorganic) fractions of total solids by ignition at 550 C.
Theoretical Foundations
Total solids dried at 103 C are ignited at 550 C; the weight lost is volatile solids (approximating organic matter) and the residue is fixed (inorganic) solids. Volatile solids (mg/L) = weight loss x 1000 / sample mL. In sewage, ~70% of suspended solids are typically volatile.
Required Apparatus & Chemicals
Laboratory Apparatus
- Evaporating dishes (pre-ignited, weighed)
- Drying oven
- Muffle furnace (550 C)
- Desiccator
- Analytical balance
Chemical Reagents
- Distilled water (dish rinsing)
- Silica gel (desiccant)
- Dilute nitric acid (dish cleaning)
Step-by-Step Practical Procedure
- Weigh a pre-ignited evaporating dish (W1).
- Evaporate a measured sample volume (100 mL) on a water bath, then dry at 103 C; weigh (W2) = total solids.
- Ignite at 550 C in the muffle furnace for 1 hour.
- Cool in a desiccator and weigh (W3).
- Volatile solids = (W2 - W3); fixed solids = (W3 - W1).
- Express each as mg/L.
Observations & Expected Results
Residue chars then glows during ignition. Sewage volatile fraction: 60-80% of total solids.
Worked Stoichiometric Calculations
Problem: 100 mL of sewage: dish 52.4000 g; after 103 C 52.4620 g; after 550 C 52.4180 g. Find volatile and fixed solids in mg/L.
Working: Total solids = 62.0 mg -> 620 mg/L. Volatile = 52.4620 - 52.4180 = 44.0 mg -> 440 mg/L. Fixed = 52.4180 - 52.4000 = 18.0 mg -> 180 mg/L. Volatile fraction = 71%, typical of domestic sewage.
Safety Precautions & Hazard Control
- Ignite in a fume-extracted furnace area; fumes are produced.
- Cool fully in a desiccator before weighing.
- Avoid spattering during evaporation.
- Use tongs for hot dishes.
Waste Disposal Protocol
Ignited residues are inert; dispose as solid lab waste.
Viva Voce Oral Defense Questions & Answers
Q: What does the volatile fraction approximate?
A: The organic matter content, which burns off at 550 C.
Q: Why not ignite above 550 C?
A: Higher temperatures decompose carbonates, inflating the volatile (organic) fraction.
Q: How are volatile solids used in treatment-plant control?
A: Volatile suspended solids (VSS) measure active biomass in aeration tanks (MLVSS).