CHEMVEN

Aluminium in Treated Water: Eriochrome Cyanine R Method

To determine residual aluminium in alum-treated drinking water.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To determine residual aluminium in alum-treated drinking water.

Theoretical Foundations

Aluminium forms a red complex with eriochrome cyanine R at pH 6 (acetate buffer), measured at 535 nm; iron interference is masked with ascorbic acid. WHO guideline: 0.2 mg/L (operational/aesthetic); excess residual alum causes turbidity and is undesirable in dialysis water.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer (535 nm)
  • Cuvettes
  • Volumetric flasks
  • Pipettes
  • Polythene beakers

Chemical Reagents

  • Eriochrome cyanine R reagent
  • Sodium acetate buffer (pH 6)
  • Ascorbic acid solution
  • Aluminium potassium sulphate stock standard

Step-by-Step Practical Procedure

  1. Take 50 mL of filtered treated-water sample.
  2. Add ascorbic acid to reduce Fe3+ interference.
  3. Add acetate buffer (pH 6) and eriochrome cyanine R.
  4. Wait 10 minutes for colour development.
  5. Measure absorbance at 535 nm against a blank.
  6. Read aluminium from the calibration curve.

Observations & Expected Results

Red colour. Well-operated plants: <0.1 mg/L residual Al; overdosed plants may exceed 0.2 mg/L.

Worked Stoichiometric Calculations

Problem: A sample gives A = 0.24 at 535 nm; calibration A = 1.20 x C (mg/L Al). Find aluminium and comment.

Working: C = 0.24/1.20 = 0.20 mg/L Al. Exactly at the WHO operational guideline of 0.2 mg/L; alum dosing should be optimised slightly downward.

Safety Precautions & Hazard Control

  • Control pH at 6.0; the complex forms only in a narrow pH range.
  • Use plastic ware; glass leaches aluminium.
  • Mask iron with ascorbic acid.
  • Develop colour for a fixed time.

Waste Disposal Protocol

Dye-containing waste goes to the organic chemical waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is residual aluminium monitored in treated water?

A: Excess alum carryover causes post-precipitation turbidity and is harmful in renal dialysis water.

Q: How is iron interference removed?

A: Ascorbic acid reduces Fe3+ to Fe2+, which does not form the coloured complex.

Q: What pH is needed and why?

A: pH 6 (acetate buffer); the Al-dye complex forms quantitatively only near this pH.

← Back to Experiments Directory