CHEMVEN

Lead in Water: Dithizone Extraction Method

To determine trace lead in drinking water by dithizone extraction spectrophotometry.

Level: UniversitySafety: Advanced lab onlyTime: 90 min
Aim of Experiment: To determine trace lead in drinking water by dithizone extraction spectrophotometry.

Theoretical Foundations

Lead forms a red complex with dithizone (diphenylthiocarbazone) extractable into chloroform at pH 8.5-9.5 after masking interferences with cyanide and citrate; absorbance is measured at 510 nm. WHO guideline for lead in drinking water is 0.01 mg/L (10 ug/L); lead is a cumulative neurotoxin, especially dangerous to children, leached mainly from old plumbing.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Separating funnels
  • Spectrophotometer (510 nm)
  • Volumetric flasks
  • Fume hood
  • pH meter

Chemical Reagents

  • Dithizone solution in chloroform
  • Sodium cyanide masking solution
  • Sodium citrate solution
  • Ammonia solution (pH adjustment)
  • Lead nitrate stock standard
  • Chloroform

Step-by-Step Practical Procedure

  1. Acid-preserve the sample at collection (pH <2).
  2. Take 100 mL sample, add citrate and cyanide masking solutions.
  3. Adjust to pH 9 with ammonia.
  4. Extract with 10 mL dithizone-chloroform, shaking 1 minute.
  5. Separate the red chloroform layer into a cuvette flask.
  6. Repeat extraction until the chloroform layer stays green (excess dithizone).
  7. Measure absorbance at 510 nm against a reagent blank and read lead from a calibration curve.

Observations & Expected Results

Red lead-dithizonate in chloroform. WHO limit 0.01 mg/L; old lead-pipe areas may exceed this at the tap.

Worked Stoichiometric Calculations

Problem: A 250 mL sample extract gives A = 0.20 at 510 nm; calibration A = 2.0 x C where C is mg/L Pb in the original sample. Find lead and comment.

Working: C = 0.20/2.0 = 0.10 mg/L Pb. This is ten times the WHO guideline of 0.01 mg/L; the supply needs corrosion control or pipe replacement.

Safety Precautions & Hazard Control

  • Cyanide masking solution is highly toxic; handle with gloves in a fume hood, never acidify.
  • Chloroform extractions in a fume hood only.
  • Acid-wash all glassware to remove lead contamination.
  • Run a full reagent blank; dithizone degrades in light.

Waste Disposal Protocol

Chloroform and cyanide-containing wastes go to their respective hazardous waste containers, never mixed with acid.

Viva Voce Oral Defense Questions & Answers

Q: Why is cyanide added?

A: It masks interfering metals (Cu, Zn, Cd) as stable cyanide complexes so only lead extracts with dithizone.

Q: Why is lead especially dangerous to children?

A: It impairs neurological development; children absorb more ingested lead and their developing brains are more vulnerable.

Q: What is the main source of lead in drinking water?

A: Corrosion of old lead pipes and lead solder in plumbing, not the source water itself.