Silica in Water: Molybdate Colorimetric Method
To determine reactive silica in water by the ammonium molybdate method.
Theoretical Foundations
Reactive (dissolved) silica forms yellow silicomolybdic acid with ammonium molybdate at pH ~1.2; oxalic acid destroys the analogous phosphomolybdate interference, and the complex is measured at 410 nm (or reduced to molybdenum blue for higher sensitivity). Silica causes hard scale in high-pressure boilers (limit often <0.1 mg/L for high-pressure steam) but is harmless in drinking water.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer (410 nm)
- Cuvettes
- Volumetric flasks
- Stopwatch
Chemical Reagents
- Ammonium molybdate solution
- Hydrochloric acid (1 N)
- Oxalic acid solution
- Sodium silicate stock standard
Step-by-Step Practical Procedure
- Prepare silica standards 0-5 mg/L as SiO2.
- Add HCl then ammonium molybdate to standards and samples; start the timer.
- After exactly 10 minutes add oxalic acid to destroy phosphate interference.
- Measure absorbance at 410 nm within the next 5 minutes.
- Plot the calibration curve and read sample silica.
- Note boiler-feed implications if silica is high.
Observations & Expected Results
Yellow colour proportional to silica. Groundwater: 10-50 mg/L SiO2; boiler feed needs <0.1-1 mg/L depending on pressure.
Worked Stoichiometric Calculations
Problem: A boiler-feed sample gives A = 0.15 at 410 nm; calibration A = 0.30 x C (mg/L SiO2). Find silica and comment for a high-pressure boiler.
Working: C = 0.15/0.30 = 0.50 mg/L SiO2. This exceeds the <0.1 mg/L limit for high-pressure boilers; demineralisation or silica removal is needed to prevent turbine-blade scale.
Safety Precautions & Hazard Control
- Keep timing exact; the yellow complex fades slowly.
- Use plastic ware; glass leaches silica into samples.
- Add oxalic acid before reading to remove phosphate interference.
- Avoid fluoride, which complexes molybdate.
Waste Disposal Protocol
Molybdate waste goes to the inorganic waste container.
Viva Voce Oral Defense Questions & Answers
Q: Why is oxalic acid added?
A: It destroys the yellow phosphomolybdate complex (phosphate interference) while leaving silicomolybdate intact.
Q: Why use plastic rather than glass ware?
A: Glass leaches soluble silica, contaminating low-level silica determinations.
Q: Why is silica critical in boilers?
A: It forms extremely hard, glassy silicate scale on turbine blades and tubes, reducing heat transfer and efficiency.