CHEMVEN

Electrical Conductivity and TDS of Water

To determine the electrical conductivity of water samples and estimate total dissolved solids (TDS).

Level: UniversitySafety: SafeTime: 30 min
Aim of Experiment: To determine the electrical conductivity of water samples and estimate total dissolved solids (TDS).

Theoretical Foundations

Conductivity measures the ability of water to carry electric current, proportional to dissolved ion concentration, and is measured with a conductivity cell (cell constant K). It is reported in uS/cm at 25 C with temperature compensation. TDS (mg/L) is approximately 0.55-0.7 times conductivity in uS/cm. WHO guideline for TDS is 500 mg/L (1000 mg/L maximum); high conductivity indicates saline or polluted water.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conductivity meter with cell
  • Beakers
  • Thermometer
  • Wash bottle

Chemical Reagents

  • Potassium chloride standard (0.01 M for cell check)
  • Distilled water
  • Dilute hydrochloric acid (electrode cleaning)

Step-by-Step Practical Procedure

  1. Calibrate/check the cell constant with 0.01 M KCl (1413 uS/cm at 25 C).
  2. Rinse the cell with the sample.
  3. Immerse the cell in the sample and record conductivity at 25 C (or temperature-compensated).
  4. Repeat for each sample.
  5. Estimate TDS = conductivity (uS/cm) x 0.65.
  6. Compare with the WHO TDS guideline of 500 mg/L.

Observations & Expected Results

Distilled water: <10 uS/cm; tap water: 200-800 uS/cm; brackish water: >2000 uS/cm. Conductivity rises about 2% per degree C.

Worked Stoichiometric Calculations

Problem: A groundwater sample shows conductivity 1150 uS/cm at 25 C. Estimate TDS and comment on potability per WHO.

Working: TDS approx = 1150 x 0.65 = 747.5 mg/L. This exceeds the WHO guideline of 500 mg/L (though below the 1000 mg/L maximum), so the water is brackish and may taste salty; treatment or blending is advisable.

Safety Precautions & Hazard Control

  • Rinse the cell with sample before measurement.
  • Ensure temperature compensation or report at 25 C.
  • Keep electrodes clean and free of deposits.
  • Avoid air bubbles on the cell plates.

Waste Disposal Protocol

KCl standard and rinses are harmless; dispose down the drain.

Viva Voce Oral Defense Questions & Answers

Q: What is the cell constant and why does it matter?

A: The ratio of electrode separation to area (cm-1); measured conductance multiplied by the cell constant gives conductivity.

Q: Why is TDS only an estimate from conductivity?

A: Different ions have different molar conductivities, so the conversion factor (0.55-0.7) depends on ionic composition.

Q: How does temperature affect conductivity?

A: Conductivity increases about 2% per degree C rise because ionic mobility increases.

← Back to Experiments Directory