Iodide by Fajans: Eosin Adsorption Indicator
To determine iodide by argentometric titration with eosin indicator.
Theoretical Foundations
Ag+ + I- -> AgI(s) (Ksp ~ 10^-16). Eosin (tetrabromofluorescein) is a stronger adsorbate than fluorescein and suits the highly adsorptive AgI: before equivalence the I--covered surface repels the dye; after equivalence Ag+ coverage adsorbs eosin, turning the precipitate pink-red. Titration is in weak acid.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipette
- 250 mL conical flask
- Wash bottle
Chemical Reagents
- Iodide solution (unknown)
- Standardised AgNO3 (0.01004 M)
- Eosin indicator (0.1%)
- Dilute acetic acid
- Dextrin solution
Step-by-Step Practical Procedure
- Pipette 25.00 mL iodide solution into a flask.
- Add dextrin, dilute acetic acid and 5 drops eosin.
- Titrate with 0.01004 M AgNO3, shaking vigorously.
- Endpoint: precipitate turns pink-red.
- Calculate I- in g/L (M = 126.90).
Observations & Expected Results
Yellow AgI suspension; pink-red precipitate at the endpoint. Typical titre about 16.40 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL iodide solution needed 16.40 mL of 0.01004 M AgNO3. Find g/L as I-.
Working: Moles Ag+ = 0.01004 x 0.01640 = 0.00016466 mol = moles I- in 25 mL = 0.0065862 M. Mass per litre = 0.0065862 x 126.90 = 0.8358 g/L.
Safety Precautions & Hazard Control
- Eosin is light-sensitive; avoid direct sunlight.
- Shake hard near the endpoint.
- Keep pH 4-5; eosin fails in strong acid.
Waste Disposal Protocol
Silver waste to silver recovery.
Viva Voce Oral Defense Questions & Answers
Q: Why eosin for iodide but fluorescein for chloride?
A: AgI adsorbs dyes far more strongly than AgCl; the more acidic dye eosin matches AgI's adsorption strength, giving a sharp change.
Q: What happens if the solution is too acidic?
A: Eosin (a weak acid dye) protonates and loses its anionic adsorbing form, so no colour change occurs.