Boiler Feed Water: High-Range Hardness
To determine very high hardness in boiler feed water by EDTA titration of a small aliquot.
Theoretical Foundations
Boiler water is concentrated by evaporation, reaching thousands of mg/L hardness as CaCO3. A small aliquot (10.00 mL) keeps the titre in range: M2+ + H2Y(2-) -> MY(2-) + 2H+ at pH 10 with EBT. Hardness above ~200 mg/L causes scale in boilers.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 10 mL pipette
- 250 mL conical flask
- Measuring cylinder
Chemical Reagents
- Boiler feed water
- Standardised EDTA (0.01004 M)
- pH 10 buffer
- Eriochrome Black T
Step-by-Step Practical Procedure
- Pipette 10.00 mL boiler water into a flask; dilute to about 100 mL.
- Add pH 10 buffer and EBT.
- Titrate with 0.01004 M EDTA to blue.
- Repeat and express as mg/L CaCO3.
Observations & Expected Results
Wine-red to blue endpoint. Typical titre about 18.60 mL.
Worked Stoichiometric Calculations
Problem: 10.00 mL boiler water needed 18.60 mL of 0.01004 M EDTA. Find hardness as mg/L CaCO3.
Working: Moles EDTA = 0.01004 x 0.01860 = 0.00018674 mol. As CaCO3: 0.00018674 x 100.09 = 0.018691 g per 10 mL = 1869 mg/L (very hard; needs softening before boiler use).
Safety Precautions & Hazard Control
- Dilute the aliquot so the indicator colour is visible.
- Use a small pipette aliquot; the hardness is very high.
- Titrate promptly after adding buffer.
Waste Disposal Protocol
Dilute solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: Why is hardness critical for boilers?
A: CaCO3/CaSO4 scale insulates heat-transfer surfaces, causing overheating, tube failure and energy waste.
Q: Why take only 10 mL?
A: At ~1800 mg/L, a 50 mL aliquot would need ~90 mL titrant; a small aliquot keeps the titre on the burette.