Aluminium by Back Titration: Excess EDTA, Zinc Back-Titrant
To determine Al3+ by adding excess EDTA and back-titrating with standard Zn2+.
Theoretical Foundations
Al3+ reacts slowly with EDTA, so excess EDTA is added and the mixture boiled at pH 5 to complete: Al3+ + H2Y(2-) -> AlY(-) + 2H+. Excess EDTA is back-titrated with standard ZnSO4 (xylenol orange, yellow to red). Al = EDTA(total) - EDTA(excess).
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL and 50 mL pipettes
- 250 mL conical flask
- Bunsen burner
Chemical Reagents
- Aluminium solution (unknown)
- Standardised EDTA (0.01004 M)
- Standard ZnSO4 (0.01004 M)
- Acetate buffer (pH 5)
- Xylenol orange indicator
Step-by-Step Practical Procedure
- Pipette 25.00 mL Al solution into a flask.
- Add 50.00 mL 0.01004 M EDTA and acetate buffer.
- Boil 5 min; cool.
- Add xylenol orange.
- Back-titrate with 0.01004 M ZnSO4 to the red endpoint.
- Calculate M(Al3+).
Observations & Expected Results
Yellow to red endpoint. Typical back-titre about 18.60 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL Al solution + 50.00 mL of 0.01004 M EDTA; back-titre 18.60 mL of 0.01004 M ZnSO4. Find M(Al3+).
Working: Total EDTA = 0.01004 x 0.05000 = 0.00050200 mol. Excess = Zn2+ used = 0.01004 x 0.01860 = 0.00018674 mol. EDTA for Al = 0.00031526 mol = moles Al3+ in 25 mL. M = 0.00031526/0.02500 = 0.012610 mol/L.
Safety Precautions & Hazard Control
- Boil to complete the slow Al-EDTA reaction.
- Cool before back-titrating; hot solutions spoil the indicator.
- Buffer at pH 5; Al(OH)3 precipitates at higher pH.
Waste Disposal Protocol
Dilute aluminium/zinc solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: Why is Al determined by back titration?
A: Al3+ is kinetically inert toward EDTA at room temperature; boiling with excess forces completion, and the leftover EDTA is easily titrated.
Q: Why xylenol orange and not EBT?
A: The back titration is at pH 5, where EBT does not function but xylenol orange does.