CHEMVEN

Aluminium by Back Titration: Excess EDTA, Zinc Back-Titrant

To determine Al3+ by adding excess EDTA and back-titrating with standard Zn2+.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To determine Al3+ by adding excess EDTA and back-titrating with standard Zn2+.

Theoretical Foundations

Al3+ reacts slowly with EDTA, so excess EDTA is added and the mixture boiled at pH 5 to complete: Al3+ + H2Y(2-) -> AlY(-) + 2H+. Excess EDTA is back-titrated with standard ZnSO4 (xylenol orange, yellow to red). Al = EDTA(total) - EDTA(excess).

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 25 mL and 50 mL pipettes
  • 250 mL conical flask
  • Bunsen burner

Chemical Reagents

  • Aluminium solution (unknown)
  • Standardised EDTA (0.01004 M)
  • Standard ZnSO4 (0.01004 M)
  • Acetate buffer (pH 5)
  • Xylenol orange indicator

Step-by-Step Practical Procedure

  1. Pipette 25.00 mL Al solution into a flask.
  2. Add 50.00 mL 0.01004 M EDTA and acetate buffer.
  3. Boil 5 min; cool.
  4. Add xylenol orange.
  5. Back-titrate with 0.01004 M ZnSO4 to the red endpoint.
  6. Calculate M(Al3+).

Observations & Expected Results

Yellow to red endpoint. Typical back-titre about 18.60 mL.

Worked Stoichiometric Calculations

Problem: 25.00 mL Al solution + 50.00 mL of 0.01004 M EDTA; back-titre 18.60 mL of 0.01004 M ZnSO4. Find M(Al3+).

Working: Total EDTA = 0.01004 x 0.05000 = 0.00050200 mol. Excess = Zn2+ used = 0.01004 x 0.01860 = 0.00018674 mol. EDTA for Al = 0.00031526 mol = moles Al3+ in 25 mL. M = 0.00031526/0.02500 = 0.012610 mol/L.

Safety Precautions & Hazard Control

  • Boil to complete the slow Al-EDTA reaction.
  • Cool before back-titrating; hot solutions spoil the indicator.
  • Buffer at pH 5; Al(OH)3 precipitates at higher pH.

Waste Disposal Protocol

Dilute aluminium/zinc solutions may be flushed with water.

Viva Voce Oral Defense Questions & Answers

Q: Why is Al determined by back titration?

A: Al3+ is kinetically inert toward EDTA at room temperature; boiling with excess forces completion, and the leftover EDTA is easily titrated.

Q: Why xylenol orange and not EBT?

A: The back titration is at pH 5, where EBT does not function but xylenol orange does.