Calcium in Water: Murexide at pH 12
To determine calcium alone in water by EDTA titration at pH 12 with murexide.
Theoretical Foundations
At pH 12-13, Mg2+ precipitates as Mg(OH)2 and does not react, so only Ca2+ is titrated: Ca2+ + H2Y(2-) -> CaY(2-) + 2H+. Murexide forms a pink complex with Ca2+; the endpoint is pink to violet (free murexide). NaOH is used (not NH3 buffer) to reach pH 12.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 50 mL pipette
- 250 mL conical flask
- pH paper
Chemical Reagents
- Water sample
- Standardised EDTA (0.01004 M)
- NaOH (1 M)
- Murexide indicator (solid mix with NaCl)
- Distilled water
Step-by-Step Practical Procedure
- Pipette 50.00 mL sample into a flask.
- Add 2 mL 1 M NaOH (check pH 12-13 with paper).
- Add a pinch of murexide-NaCl mix (pink).
- Titrate with 0.01004 M EDTA to the violet endpoint.
- Repeat and express Ca as mg/L CaCO3.
Observations & Expected Results
Pink to violet endpoint; a white Mg(OH)2 haze may appear. Typical titre about 8.40 mL.
Worked Stoichiometric Calculations
Problem: 50.00 mL sample needed 8.40 mL of 0.01004 M EDTA at pH 12. Find Ca as mg/L CaCO3.
Working: Moles EDTA = 0.01004 x 0.00840 = 0.000084336 mol = moles Ca2+. As CaCO3: 0.000084336 x 100.09 = 0.0084412 g per 50 mL = 169 mg/L.
Safety Precautions & Hazard Control
- Confirm pH is 12-13; below 12, Mg2+ interferes.
- Titrate promptly; CaCO3 can precipitate from air CO2 at high pH.
- Use solid murexide mix; its solution decomposes.
Waste Disposal Protocol
Dilute alkaline solutions: neutralise, then flush with water.
Viva Voce Oral Defense Questions & Answers
Q: Why doesn't Mg2+ interfere at pH 12?
A: It precipitates quantitatively as Mg(OH)2 (Ksp ~ 10^-11), leaving only Ca2+ free to complex with EDTA.
Q: Why is NaOH used instead of the pH 10 buffer?
A: The ammonia buffer cannot reach pH 12; NaOH provides the high hydroxide concentration needed to precipitate Mg2+.