Total Water Hardness: Ca plus Mg by EDTA
To determine total hardness (Ca2+ + Mg2+) of tap water as mg/L CaCO3.
Theoretical Foundations
At pH 10 (NH3/NH4Cl buffer), EDTA complexes both Ca2+ and Mg2+ 1:1: M2+ + H2Y(2-) -> MY(2-) + 2H+. EBT indicator goes wine-red to blue. Hardness is conventionally expressed as mg/L CaCO3 (M = 100.09).
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 50 mL pipette
- 250 mL conical flask
- Measuring cylinder
Chemical Reagents
- Tap water sample
- Standardised EDTA (0.01004 M)
- pH 10 buffer
- Eriochrome Black T indicator
- Distilled water
Step-by-Step Practical Procedure
- Pipette 50.00 mL tap water into a conical flask.
- Add 5 mL pH 10 buffer.
- Add 3 drops EBT.
- Titrate with 0.01004 M EDTA to pure blue.
- Repeat and express hardness as mg/L CaCO3.
Observations & Expected Results
Wine-red to blue endpoint. Typical titre about 12.60 mL.
Worked Stoichiometric Calculations
Problem: 50.00 mL tap water needed 12.60 mL of 0.01004 M EDTA. Find total hardness as mg/L CaCO3.
Working: Moles EDTA = 0.01004 x 0.01260 = 0.00012650 mol = moles (Ca2+ + Mg2+). As CaCO3: 0.00012650 x 100.09 = 0.012661 g per 50 mL = 253 mg/L (moderately hard).
Safety Precautions & Hazard Control
- Titrate promptly; ammonia buffer loses NH3 on standing.
- If the endpoint is sluggish, Mg2+ may be very low: add a little Mg-EDTA.
- Use freshly prepared EBT solution.
Waste Disposal Protocol
Dilute solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: Why is hardness expressed as CaCO3?
A: Ca and Mg have different masses; converting to CaCO3 equivalents gives one comparable number for total divalent cations.
Q: What does the buffer do besides fixing pH?
A: Ammonia also keeps Mg2+ from precipitating as hydroxide at pH 10 long enough to be titrated.