CHEMVEN

Formaldehyde by Alkaline Iodine: Back Titration

To determine formaldehyde by the hypoiodite (Romijn) method with back titration.

Level: UniversitySafety: Needs supervisionTime: 75 min
Aim of Experiment: To determine formaldehyde by the hypoiodite (Romijn) method with back titration.

Theoretical Foundations

In NaOH, iodine forms hypoiodite which oxidises formaldehyde: HCHO + I2 + 3NaOH -> HCOONa + 2NaI + 2H2O (1:1). Excess I2 is acidified and back-titrated with thiosulfate. A blank standardises the iodine added.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 5 mL pipette
  • 250 mL iodine flasks (stoppered)
  • Wash bottle

Chemical Reagents

  • Formalin sample
  • Iodine solution (0.1000 M, in KI)
  • NaOH (1 M)
  • Dilute H2SO4
  • Standardised Na2S2O3 (0.1000 M)
  • Starch indicator

Step-by-Step Practical Procedure

  1. Pipette 5.00 mL formalin into an iodine flask.
  2. Add 25.00 mL 0.1000 M iodine and 10 mL 1 M NaOH; stopper.
  3. Keep in the dark 15 min.
  4. Acidify with dilute H2SO4.
  5. Back-titrate with 0.1000 M thiosulfate, starch near the end.
  6. Run a blank identically; calculate g/L HCHO (M = 30.03).

Observations & Expected Results

Blank about 49.80 mL; sample about 18.60 mL; blue to colourless endpoint.

Worked Stoichiometric Calculations

Problem: 5.00 mL sample; blank 49.80 mL, sample 18.60 mL of 0.1000 M thiosulfate. Find g/L HCHO.

Working: I2 in blank = 0.1000 x 0.04980/2 = 0.0024900 mol. Excess I2 in sample = 0.1000 x 0.01860/2 = 0.00093000 mol. I2 consumed = 0.0015600 mol = moles HCHO. Mass = 0.0015600 x 30.03 = 0.046847 g per 5 mL = 9.37 g/L.

Safety Precautions & Hazard Control

  • Keep the alkaline iodine mixture in the dark; hypoiodite disproportionates in light.
  • Acidify before titrating; thiosulfate decomposes in the alkaline mixture otherwise.
  • Formaldehyde vapours: ventilate.

Waste Disposal Protocol

Iodide/formate waste to halogenated aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is the excess iodine back-titrated instead of titrating directly?

A: The oxidation needs time (15 min) to complete; excess guarantees completion and the remainder is measured accurately.

Q: Why must the mixture be acidified before the back titration?

A: In alkali, iodine exists as hypoiodite/iodate which do not give the clean I2-thiosulfate stoichiometry.

← Back to Experiments Directory