CHEMVEN

Hydrazine by Iodate Titration (ICl Endpoint)

To determine hydrazine sulfate by titration with standard potassium iodate.

Level: UniversitySafety: Advanced lab onlyTime: 75 min
Aim of Experiment: To determine hydrazine sulfate by titration with standard potassium iodate.

Theoretical Foundations

In conc. HCl with ICl present: IO3(-) + N2H4 + 2H+ + Cl- -> ICl + N2 + 3H2O (1:1). The endpoint is the persistence of ICl colour in a chloroform layer (or the first excess iodate detected with starch-iodide paper). Hydrazine is a rocket propellant and oxygen scavenger; it is toxic and a suspected carcinogen.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 25 mL pipette
  • 250 mL iodine flask
  • Fume cupboard

Chemical Reagents

  • Hydrazine sulfate solution (unknown)
  • Standard KIO3 (0.02500 M)
  • Conc. HCl
  • Chloroform
  • Starch-iodide paper

Step-by-Step Practical Procedure

  1. Pipette 25.00 mL hydrazine solution into an iodine flask.
  2. Add 20 mL conc. HCl and 5 mL chloroform.
  3. Titrate with 0.02500 M KIO3 with vigorous shaking.
  4. Endpoint: the chloroform layer retains a faint violet ICl colour, or starch-iodide paper turns blue.
  5. Calculate g/L as N2H6SO4 (M = 130.12).

Observations & Expected Results

Chloroform layer flashes violet then clears; final persistent faint colour marks the endpoint. Typical titre about 16.40 mL.

Worked Stoichiometric Calculations

Problem: 25.00 mL solution needed 16.40 mL of 0.02500 M KIO3. Find g/L as hydrazine sulfate.

Working: Moles IO3(-) = 0.02500 x 0.01640 = 0.00041000 mol = moles N2H4 (1:1). Mass as N2H6SO4 = 0.00041000 x 130.12 = 0.053349 g per 25 mL = 2.134 g/L.

Safety Precautions & Hazard Control

  • Hydrazine is toxic and a suspected carcinogen: fume cupboard, gloves, no inhalation.
  • Conc. HCl handling: face shield.
  • Chloroform waste to halogenated organic waste.

Waste Disposal Protocol

Hydrazine residues are hazardous: quench as directed and collect in toxic waste.

Viva Voce Oral Defense Questions & Answers

Q: What is oxidised and what is reduced here?

A: Hydrazine (N -2) is oxidised to N2 (0); iodate (+5) is reduced to ICl (+1).

Q: Why is chloroform added?

A: ICl partitions into chloroform giving a visible violet colour that signals the first excess of iodate.