CHEMVEN

Peroxide Value of Edible Oil: Iodometric

To determine the peroxide value (meq O2/kg) of an edible oil as a rancidity index.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To determine the peroxide value (meq O2/kg) of an edible oil as a rancidity index.

Theoretical Foundations

Lipid hydroperoxides oxidise iodide in acetic acid/chloroform: ROOH + 2I- + 2H+ -> ROH + I2 + H2O. Liberated I2 is titrated with dilute thiosulfate. PV = (Vs - Vb) x M x 1000 / mass(g) meq/kg. Fresh oils are below 10; above 20 is rancid.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 250 mL iodine flask
  • Analytical balance
  • Measuring cylinder

Chemical Reagents

  • Oil sample
  • Acetic acid-chloroform (3:2)
  • KI (saturated solution)
  • Standardised Na2S2O3 (0.01000 M)
  • Starch indicator
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh accurately about 5.000 g oil into an iodine flask.
  2. Add 30 mL acetic acid-chloroform; swirl to dissolve.
  3. Add 1 mL saturated KI; stopper; keep dark 5 min.
  4. Add 75 mL water; titrate with 0.01000 M thiosulfate, starch near the end.
  5. Run a blank identically.
  6. Calculate PV in meq/kg.

Observations & Expected Results

Brown I2 liberated; blue to colourless endpoint. Typical sample 6.40 mL, blank 0.20 mL.

Worked Stoichiometric Calculations

Problem: 5.000 g oil; sample 6.40 mL, blank 0.20 mL of 0.01000 M thiosulfate. Find peroxide value.

Working: Net titre = 6.20 mL. PV = 6.20 x 0.01000 x 1000 / 5.000 = 12.4 meq O2/kg (slightly oxidised but acceptable).

Safety Precautions & Hazard Control

  • Work fast once KI is added; peroxides keep reacting.
  • Chloroform is toxic: use in a fume cupboard.
  • The blank corrects for iodine liberated by dissolved oxygen.

Waste Disposal Protocol

Chloroform-containing waste to halogenated organic waste.

Viva Voce Oral Defense Questions & Answers

Q: What does peroxide value actually measure?

A: Primary oxidation products (hydroperoxides) of unsaturated fats; it tracks early rancidity before off-flavours appear.

Q: Why is the titration done in acetic acid-chloroform?

A: Chloroform dissolves the oil and acetic acid provides the protons needed for ROOH + 2I- + 2H+ -> I2.

← Back to Experiments Directory