Vitamin C Powder: Iodometric Assay of Ascorbic Acid
To determine the purity of ascorbic acid powder by direct iodine titration.
Theoretical Foundations
Ascorbic acid is oxidised to dehydroascorbic acid: C6H8O6 + I2 -> C6H6O6 + 2HI (1:1). The titration uses standard iodine with starch; the first excess I2 gives the blue endpoint. HPO3 stabilises ascorbic acid against air oxidation during preparation.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 100 mL volumetric flask
- 250 mL conical flask
- Analytical balance
- Mortar
Chemical Reagents
- Ascorbic acid powder (vitamin C)
- Standard iodine solution (0.05000 M)
- HPO3 (metaphosphoric acid) solution
- Starch indicator
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately about 0.2000 g ascorbic acid powder.
- Dissolve in HPO3 solution; make up to 100.0 mL.
- Pipette 25.00 mL into a flask.
- Titrate with 0.05000 M iodine to the first permanent blue with starch.
- Repeat and calculate % purity (M = 176.12).
Observations & Expected Results
Colourless to blue endpoint. Typical titre about 5.68 mL.
Worked Stoichiometric Calculations
Problem: 0.2000 g ascorbic acid powder dissolved to 100.0 mL; 25.00 mL aliquot needed 5.68 mL of 0.05000 M I2. Find % purity (M = 176.12).
Working: Moles I2 = 0.05000 x 0.00568 = 0.00028400 mol = moles ascorbic acid in aliquot. In 100 mL: 4 x 0.00028400 = 0.0011360 mol. Mass = 0.0011360 x 176.12 = 0.20007 g. Purity = 0.20007/0.2000 x 100 = 100.0%.
Safety Precautions & Hazard Control
- Prepare solutions fresh; ascorbic acid oxidises in air.
- HPO3 stabiliser prevents metal-catalysed oxidation.
- Titrate promptly after dissolution.
Waste Disposal Protocol
Dilute iodide solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: Why is starch not added at the start here?
A: The titration is direct with iodine as titrant; starch is present from near the start in some protocols, but adding it near the end keeps the endpoint sharp and avoids starch-iodine clumps.
Q: Why does the method use HPO3?
A: Metaphosphoric acid chelates metal ions and provides acidity, both of which slow the air oxidation of ascorbic acid before titration.