Standardisation of Thiosulfate: Potassium Iodate Method
To standardise Na2S2O3 against KIO3 primary standard as an alternative to dichromate.
Theoretical Foundations
IO3(-) + 5I- + 6H+ -> 3I2 + 3H2O. KIO3 (M = 214.00) is an excellent primary standard: stable, non-hygroscopic, high purity. Each iodate liberates 3 I2, consuming 6 thiosulfate: a large titre per gram weighed, reducing error.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipette
- 250 mL iodine flask
- 250 mL volumetric flask
- Analytical balance
Chemical Reagents
- Na2S2O3 (approx 0.1 M)
- KIO3 AR (dried at 120 C)
- KI crystals
- Dilute HCl
- Starch indicator
Step-by-Step Practical Procedure
- Weigh about 0.8917 g KIO3; dissolve and make up to 250.0 mL.
- Pipette 25.00 mL into an iodine flask; add KI and dilute HCl.
- Keep in the dark 5 min.
- Titrate with thiosulfate to straw-yellow; add starch; finish to colourless.
- Repeat and calculate M(Na2S2O3).
Observations & Expected Results
Brown iodine liberated; starch-blue to colourless endpoint. Typical titre 25.00 mL.
Worked Stoichiometric Calculations
Problem: 0.8917 g KIO3 (M = 214.00) to 250.0 mL; 25.00 mL aliquot needed 25.00 mL thiosulfate. Find M.
Working: Moles IO3(-) in aliquot = (0.8917/214.00) x 0.1 = 0.00041668 mol. Moles I2 = 3 x 0.00041668 = 0.00125004 mol. Moles thio = 2 x 0.00125004 = 0.00250008 mol. M = 0.00250008/0.02500 = 0.1000 mol/L.
Safety Precautions & Hazard Control
- Dry KIO3 at 120 C before weighing.
- Acidify adequately; the reaction needs 6 H+ per iodate.
- Protect from light during the standing period.
Waste Disposal Protocol
Iodine-containing waste to halogenated aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is KIO3 considered superior to K2Cr2O7 for this?
A: It is non-hygroscopic, indefinitely stable, and avoids toxic chromium waste.
Q: How many moles of thiosulfate does one mole of iodate consume?
A: Six: 1 IO3(-) -> 3 I2 -> 6 S2O3(2-).