Theoretical Foundations

In acid: 2MnO4(-) + 5H2O2 + 6H+ -> 2Mn2+ + 5O2 + 8H2O. H2O2 acts as the reductant (O goes from -1 to 0). Titration is done cold and in H2SO4; permanganate is self-indicating. The sample is diluted so the titre is convenient.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 10 mL and 25 mL pipettes
  • 100 mL volumetric flask
  • 250 mL conical flask

Chemical Reagents

  • H2O2 sample (approx 3% w/v)
  • Standardised KMnO4 (0.02008 M)
  • Dilute H2SO4 (2 M)
  • Distilled water

Step-by-Step Practical Procedure

  1. Pipette 10.00 mL H2O2 into a 100 mL flask; make up to the mark.
  2. Pipette 25.00 mL of the diluted solution into a flask.
  3. Add 10 mL 2 M H2SO4.
  4. Titrate with KMnO4 to the first permanent pink.
  5. Repeat and calculate g/L H2O2 (M = 34.01).

Observations & Expected Results

Effervescence (O2) during titration; faint pink endpoint. Typical titre about 21.30 mL.

Worked Stoichiometric Calculations

Problem: 10.00 mL sample diluted to 100 mL; 25.00 mL aliquot needed 21.30 mL of 0.02008 M KMnO4. Find g/L H2O2.

Working: Moles MnO4(-) = 0.02008 x 0.02130 = 0.00042770 mol. Moles H2O2 in aliquot = 0.00042770 x 5/2 = 0.00106926 mol. In 100 mL: 0.00427704 mol. Mass per 10 mL sample = 0.00427704 x 34.01 = 0.14546 g = 14.5 g/L (about 1.45% w/v).

Safety Precautions & Hazard Control

  • Titrate at room temperature; heat decomposes H2O2.
  • Use fresh H2SO4-acidified medium; do not use HCl.
  • Keep H2O2 stock cool and dark; it decomposes on standing.

Waste Disposal Protocol

Dilute acidic manganese waste to heavy-metal aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Is H2O2 the oxidant or reductant here?

A: Reductant: oxygen is oxidised from -1 in H2O2 to 0 in O2, donating electrons to Mn(VII).

Q: Why is the titration done cold?

A: H2O2 decomposes to water and oxygen when heated, which would lower the titre.