CHEMVEN

Stoichiometry by Job's Method: Iron-Phenanthroline Complex

To find the Fe:phenanthroline combining ratio by the method of continuous variation at 510 nm.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To find the Fe:phenanthroline combining ratio by the method of continuous variation at 510 nm.

Theoretical Foundations

In Job's method, the total molarity [Fe] + [phen] is held constant while the mole fraction of Fe varies from 0 to 1. Absorbance at 510 nm (complex only) peaks at the mole fraction matching the complex stoichiometry. For [Fe(phen)3]²⁺ the maximum occurs at x(Fe) = 1/(1+3) = 0.25.

Required Apparatus & Chemicals

Laboratory Apparatus

  • UV-Vis spectrophotometer
  • Test tubes or flasks (11)
  • Pipettes
  • Cuvettes

Chemical Reagents

  • Fe(II) solution (1.0 × 10⁻³ M)
  • 1,10-phenanthroline (1.0 × 10⁻³ M)
  • Acetate buffer (pH 4.5)
  • Hydroxylamine hydrochloride

Step-by-Step Practical Procedure

  1. Prepare 11 mixtures with Fe mole fractions 0.0-1.0, total volume 10 mL, total conc. 1.0 × 10⁻³ M.
  2. Add buffer and hydroxylamine to each; wait 15 min.
  3. Zero at 510 nm with a blank.
  4. Read absorbances of all mixtures.
  5. Plot A510 versus x(Fe).
  6. Locate the maximum and deduce the stoichiometry.

Observations & Expected Results

Absorbance rises to a sharp maximum at x(Fe) = 0.25 then falls; the Job plot is triangular for a stable complex.

Worked Stoichiometric Calculations

Problem: The Job plot maximum occurs at x(Fe) = 0.25. What is the Fe:phenanthroline ratio in the complex?

Working: x(Fe) = n(Fe)/(n(Fe) + n(phen)) = 0.25 → n(phen)/n(Fe) = 0.75/0.25 = 3. The complex is [Fe(phen)3]²⁺, ratio 1:3.

Safety Precautions & Hazard Control

  • Keep total molarity exactly constant across mixtures.
  • Use Fe(II) (hydroxylamine) so only one complex forms.
  • Hold pH constant with buffer.
  • Allow full colour development before reading.

Waste Disposal Protocol

Phenanthroline waste to the organic-aqueous waste bottle.

Viva Voce Oral Defense Questions & Answers

Q: Why keep total concentration constant?

A: So that changes in absorbance reflect only the changing mole fraction, not changing total material.

Q: What does a rounded (not sharp) maximum indicate?

A: A less stable complex with significant dissociation at the maximum.

Q: Why does the peak position give the formula?

A: Maximum complex forms when reactants are mixed in their stoichiometric ratio, consuming both fully.