CHEMVEN

Lead Determination: Dithizone Method at 520 nm

To determine trace lead in water by dithizone extraction into chloroform at 520 nm.

Level: UniversitySafety: Advanced lab onlyTime: 2 h
Aim of Experiment: To determine trace lead in water by dithizone extraction into chloroform at 520 nm.

Theoretical Foundations

Pb²⁺ forms the red lead dithizonate extractable into chloroform at pH 8-9 (λmax 520 nm, ε ≈ 6.8 × 10⁴). Cyanide masks most interfering metals (Cu, Zn, Cd) while lead still extracts. The very high absorptivity permits determination down to ~0.01 mg L⁻¹, relevant to the 0.01 mg L⁻¹ drinking-water guideline.

Required Apparatus & Chemicals

Laboratory Apparatus

  • UV-Vis spectrophotometer
  • Separating funnels
  • Volumetric flasks
  • Pipettes
  • Cuvettes
  • Gloves

Chemical Reagents

  • Pb standard (0.1 mg L⁻¹)
  • Dithizone in chloroform
  • Ammoniacal buffer (pH 9)
  • Potassium cyanide solution (masking)
  • Water sample

Step-by-Step Practical Procedure

  1. Place standards 0-0.1 mg L⁻¹ Pb and the sample in funnels.
  2. Add cyanide masking solution and pH 9 buffer.
  3. Extract with 10 mL dithizone solution; shake 2 min.
  4. Separate and dilute the chloroform layer to 50 mL.
  5. Zero at 520 nm with CHCl3; read absorbances.
  6. Determine lead and compare with the 0.01 mg L⁻¹ guideline.

Observations & Expected Results

Red extract proportional to lead; cyanide keeps competing metals aqueous; A520 linear at trace levels.

Worked Stoichiometric Calculations

Problem: An extract gives A = 0.260 at 520 nm (ε = 6.80 × 10⁴, l = 1 cm). Find Pb in mg L⁻¹.

Working: c = 0.260/6.80 × 10⁴ = 3.82 × 10⁻⁶ mol L⁻¹ = 3.82 × 10⁻⁶ × 207.2 × 1000 = 0.792 mg L⁻¹ Pb (above the 0.01 mg L⁻¹ guideline).

Safety Precautions & Hazard Control

  • Lead and cyanide are both highly toxic: gloves, fume cupboard, strict waste control.
  • Never acidify cyanide waste (HCN gas).
  • Mask with cyanide before adding dithizone.
  • Avoid bismuth and thallium, which co-extract.

Waste Disposal Protocol

Cyanide waste and lead/chloroform waste each to their dedicated labeled bottles.

Viva Voce Oral Defense Questions & Answers

Q: Why add cyanide?

A: Cyanide complexes Cu, Zn, Cd and Ni so they stay aqueous, while lead dithizonate still extracts at pH 9, giving selectivity.

Q: Why is the method so sensitive?

A: Lead dithizonate has ε ≈ 6.8 × 10⁴, among the highest in colorimetry, so trace lead gives measurable colour.

Q: Why must cyanide waste never meet acid?

A: Acid liberates deadly HCN gas from cyanide solutions.

← Back to Experiments Directory