Lead as Lead Dioxide: Anodic Electrogravimetry
Determine lead in solder by anodic deposition as PbO2.
Theoretical Foundations
Lead can be deposited on the anode as lead dioxide: Pb2+ + 2H2O → PbO2(s) + 4H+ + 2e-. The weighed PbO2 is converted to lead with the gravimetric factor M_Pb/M_PbO2 = 207.2/239.2 = 0.8662. Deposition is done in nitric acid at about 90 C with high current density; tin, if present, is removed first as metastannic acid.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- Platinum gauze anode (weighed)
- DC power supply
- 250 mL beaker
- Hot plate
- Fume cupboard
- Oven
- Desiccator
Chemical Reagents
- Solder sample (Pb-Sn)
- Nitric acid, concentrated and dilute
- Distilled water
Step-by-Step Practical Procedure
- Weigh the Pt anode accurately.
- Weigh 0.5 g solder; dissolve in 15 mL conc. HNO3 in a fume cupboard.
- Evaporate to precipitate metastannic acid; filter it off.
- Dilute the filtrate to 150 mL with dilute HNO3; heat to 90 C.
- Electrolyse at 3-5 A for 45 minutes; brown PbO2 coats the anode.
- Wash the anode with the current on; dry at 180 C to constant mass.
- Weigh; calculate % Pb using GF = 0.8662.
Observations & Expected Results
Chocolate-brown adherent PbO2 on the anode; typical mass about 0.22 g from 0.5 g solder.
Worked Stoichiometric Calculations
Problem: 0.5000 g of solder gave 0.2150 g PbO2. Calculate % Pb. (GF_Pb = 0.8662)
Working: Mass Pb = 0.2150 × 0.8662 = 0.1862 g. % Pb = (0.1862/0.5000) × 100 = 37.25%.
Safety Precautions & Hazard Control
- Remove tin first; it contaminates the anode deposit.
- Dry PbO2 at 180 C; higher temperatures decompose it.
- Keep the current on while washing the anode.
Waste Disposal Protocol
Acidic lead residues to heavy-metal waste; lead waste is toxic — collect all of it.
Viva Voce Oral Defense Questions & Answers
Q: Write the anode reaction for lead deposition.
A: Pb2+ + 2H2O → PbO2(s) + 4H+ + 2e-.
Q: Why dry PbO2 at 180 C and not higher?
A: Above ~200 C PbO2 begins to lose oxygen, giving non-stoichiometric oxides and low results.
Q: Why is this called anodic deposition?
A: The analyte deposits on the positive electrode (anode) by oxidation, the reverse of the usual cathodic metal deposition.