Effect of Current Density on Copper Deposition
Show that excessive current density lowers current efficiency in copper electrogravimetry.
Theoretical Foundations
Faraday's law gives the theoretical deposit: m = Q·M/(n·F). At moderate current density all current deposits copper (Cu2+ + 2e- → Cu). At very high current density the cathode potential shifts negative enough to evolve hydrogen as well (2H+ + 2e- → H2), wasting current: current efficiency = (actual/theoretical) × 100 falls, and the deposit turns dark and powdery.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- Platinum electrodes
- DC power supply with ammeter
- Two 250 mL beakers
- Oven
- Desiccator
Chemical Reagents
- Copper sulfate standard solution (equal aliquots)
- Sulfuric acid, dilute
- Distilled water
- Ethanol
Step-by-Step Practical Procedure
- Place identical aliquots of standard CuSO4 solution in two beakers; acidify equally.
- Weigh two cathodes.
- Electrolyse beaker A at 1 A (low current density) for 30 minutes.
- Electrolyse beaker B at 5 A (high current density) for the same charge-equivalent time adjusted to equal coulombs.
- Wash (current on), dry and weigh both deposits.
- Calculate current efficiency for each vs Faraday's law.
Observations & Expected Results
Deposit A is smooth and pink; deposit B is dark, rough and powdery, with visible gas bubbles during electrolysis.
Worked Stoichiometric Calculations
Problem: 2.00 A for 30.0 min should deposit 1.186 g Cu (Faraday's law). The high-current-density run gave 1.152 g. Calculate the current efficiency.
Working: Theoretical m = (3600 × 63.55)/(2 × 96485) = 1.186 g. Efficiency = (1.152/1.186) × 100 = 97.2% — the missing 2.8% of charge evolved hydrogen.
Safety Precautions & Hazard Control
- Control the current, not just the voltage.
- Vent hydrogen safely; no flames near the cell.
- Compare equal total charge, not equal time, when currents differ.
Waste Disposal Protocol
Electrolytes to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: What is current efficiency?
A: The fraction of the total charge that produces the desired electrode reaction; side reactions like H2 evolution lower it below 100%.
Q: Why does the high-current-density deposit look dark and powdery?
A: Hydrogen bubbles disrupt crystal growth, giving a rough, burnt deposit that may also trap electrolyte.