Iron in Steel Wire: High-Purity Matrix
Determine iron in mild-steel wire (≈99% Fe) by hydroxide gravimetry.
Theoretical Foundations
Steel wire dissolves in HCl/HNO3; alloying elements (Mn, Si) are at low levels and mostly stay in solution or are filtered as silica. Fe3+ is precipitated with ammonia: Fe3+ + 3OH- → Fe(OH)3(s), then ignited to Fe2O3 (GF = 0.6994). For a ~99% Fe matrix the method tests precision: small absolute errors are visible as deviations from 100%.
Required Apparatus & Chemicals
Laboratory Apparatus
- Analytical balance
- 400 mL beaker
- Hot plate
- Ashless filter paper
- Porcelain crucible
- Muffle furnace
- Desiccator
Chemical Reagents
- Steel wire pieces
- Hydrochloric acid, dilute
- Nitric acid, concentrated
- Ammonia solution, dilute
- Ammonium chloride, solid
- Distilled water
Step-by-Step Practical Procedure
- Weigh accurately 0.4 g of clean steel wire pieces.
- Dissolve in 15 mL dilute HCl with 2 mL conc. HNO3 on a hot plate.
- Dilute to 200 mL; filter off any silica residue.
- Add NH4Cl, heat to boiling, precipitate with dilute ammonia.
- Digest, filter, wash with hot 1% NH4Cl until chloride-free.
- Ignite at 850 C to constant mass; weigh Fe2O3 and calculate % Fe.
Observations & Expected Results
Wire dissolves with effervescence; brown precipitate ignites to reddish Fe2O3, typically about 0.57 g from 0.4 g wire.
Worked Stoichiometric Calculations
Problem: 0.4000 g of steel wire gave 0.5680 g Fe2O3. Calculate % Fe.
Working: Mass Fe = 0.5680 × 0.6994 = 0.3973 g. % Fe = (0.3973/0.4000) × 100 = 99.31%, as expected for mild steel.
Safety Precautions & Hazard Control
- Clean the wire of oil/rust before weighing.
- Oxidise fully to Fe3+.
- Avoid a large excess of ammonia, which makes the precipitate slimy.
Waste Disposal Protocol
Acidic filtrates neutralised; iron residues to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is this determination a good precision test?
A: Because the true value is near 100%, any procedural error shows up directly as a deviation from 100% without being masked by matrix corrections.
Q: What happens to manganese in this procedure?
A: Mn2+ partly precipitates as Mn(OH)2 and oxidises on ignition to Mn3O4, causing a small positive error; it is negligible in mild steel.